background image

 

14 

 

¾

 Wiring 

While wiring, first insert the SFP modular into the SFP slot in the device, and 

then plug the optical fiber into the SFP module. See Figure 14 

 

Figure 14 SFP Gigabit Optical Fiber Transceiver Wiring 

5.3 Power 

According to the power input requirements, use a 5.08mm-spacing terminal block 

to connect the power cable. 

 

Note

: The cross section area of the power cable is required to be greater than 0.75mm

2

 and less 

than 2.5mm

2

. The grounding resistance requirement: <5

Ω

 

z

 

5.08mm power terminal block pin number is shown in Figure 15

 

 

 

 

 

 

Figure 15 Pin 5.08mm Power Terminal Block

 

z

 

5.08mm power terminal block contact definition 

 

 

Summary of Contents for KIEN1008G

Page 1: ...et Switch Hardware Installation Manual Kyland Technology Co LTD Publication Date Oct 2011 Version V1 0 Customer Service Hotline 8610 88796676 FAX 8610 88796678 Website http www kyland cn E mail support kyland biz No 1 12 02 1029 0 ...

Page 2: ... up to date as possible This document is not guaranteed to be error free and we reserve the right to amend it without notice All rights reserved No part of this documentation may be excerpted reproduced translated annotated or duplicated in any form or by any means without the prior written permission of KYLAND Corporation Copyright 2011 KYLAND Technology CO LTD ...

Page 3: ...tie or wrap the cable to prevent fire z Power connectors and other equipment connectors should be firmly interconnected and checked frequently z Do not repair the equipment by yourself unless it is clearly specified in the manual z Please keep the equipment clean if necessary wipe the equipment with soft cotton cloth In the following cases please immediately cut off the power supply and contact ou...

Page 4: ...5 3 1 Front Panel 5 3 2 Top Panel 7 4 Mounting 7 4 1 Mounting 7 4 2 Mounting Steps 8 5 Cable Connection 11 5 1 10 100 1000Base T X 11 5 2 Combo port 12 5 3 Power 14 5 4 Grounding 15 6 LED Indicators 17 7 Product Models and Accessories 18 8 Basic Features and Specifications 18 ...

Page 5: ...ial Ethernet switch that can be applied extensively in wind power distribution network automation subway PIS power SCADA wastewater treatment metallurgy intelligent transportation rail transit and many other industries KIEN1008G industrial Ethernet switch supports DIN Rail and panel mounting It supports IP40 protection class and provides abundant Gigabit ports 3 Structure and Interface 3 1 Front P...

Page 6: ... ports 6 GE1 GE6 six 10 100 1000Base T X RJ45 ports 7 RJ45port Speed LED 8 RJ45portLink ACT LED Figure 1 Front Panel 1 z KIEN1008G 8GE front panel is shown in Figure 2 below 1 PWR1 Power 1 LED 2 PWR2 Power 2 LED 3 GE1 GE8 eight 10 100 1000Base T X RJ45 ports 4 RJ45port Speed LED 5 RJ45portLink ACT LED Figure 2 Front Panel 2 ...

Page 7: ...7 3 2 Top Panel 1 Terminal block for power input 2 Screw hole for grounding Figure 3 Top Panel 4 Mounting 4 1 Mounting z Dimension Drawing for DIN Rail Mounting Unit mm Figure 4 DIN Rail Mounting ...

Page 8: ...osition for KIEN1008G and ensure that there is adequate space Step 2 Insert the top of the DIN Rail into the spring supported slot of the DIN Rail connecting seat in the rear panel of KIEN1008G as seen below move the device in the direction of arrow 2 to put the whole Din Rail into place verify the KIEN1008G is firmly mounted on the DIN Rail as shown below Figure 6 DIN Rail Mounting ...

Page 9: ...nel Mounting The specific steps are as follows Step 1 Select the mounting position for KIEN1008G on the wall or in cabinet ensure that there is adequate space for the switch Step 2 Drill 4 holes on the selected position according to the panel mounting dimension drawings use a cross screwdriver to screw 4 cross slot screws M3 10 into holes Don t tighten the screws completely leave about 5mm of spac...

Page 10: ... KIEN1008G from wall or cabinet The specific steps are as follows Step 1 Use a screwdriver to loosen 4 screws move the device up to let screws into 4 holes with the diameter of 6 5mm Ф6 5 Step 2 Unscrew the screws from wall or cabinet remove the device from wall or cabinet Figure 9 Panel Dismounting ...

Page 11: ...of 10 100 1000Base T X Pin MDI MDI X 1 Output Receiving data TRD0 Output Receiving data TRD1 2 Output Receiving data TRD0 Output Receiving data TRD1 3 Output Receiving data TRD1 Output Receiving data TRD0 4 Output Receiving data TRD2 Output Receiving data TRD3 5 Output Receiving data TRD2 Output Receiving data TRD3 6 Output Receiving data TRD1 Output Receiving data TRD0 7 Output Receiving data TRD...

Page 12: ...iring z 1000M crossover cable wiring Figure 12 1000M Crossover Cable Wiring 5 2 Combo port A Combo port is on the front panel which consists of one RJ45 port and one gigabit SFP slot that accepts a modular SFP optical fiber transceiver The RJ45 ...

Page 13: ...M Single Mode S Single Mode S Single Mode S Single Mode S Center Wavelength nm 850 1310 1310 1550 1550 Transmission Distance Km 0 55 10 40 60 80 Application Range of Transmission Distance Km 0 0 55 0 10 12 40 24 60 27 80 Transmitting Optical Power Mini dBm 11 10 4 3 2 Max dBm 2 3 3 4 5 Receiving Sensitivity dBm 18 21 23 22 25 Overload Optical Power dBm 0 3 3 3 3 Figure 13shows an example of an SFP...

Page 14: ...Power According to the power input requirements use a 5 08mm spacing terminal block to connect the power cable Note The cross section area of the power cable is required to be greater than 0 75mm2 and less than 2 5mm2 The grounding resistance requirement 5Ω z 5 08mm power terminal block pin number is shown in Figure 15 Figure 15 Pin 5 08mm Power Terminal Block z 5 08mm power terminal block contact...

Page 15: ...WR2 N 5 PWR2 PWR2 L z Wiring and mounting Step 1 Take the power terminal block off KIEN1008G Step 2 Insert the power cable into the terminal block and fix the power cable Step 3 Put the terminal block back to KIEN1008G with the connected cable 5 4 Grounding z Chassis grounding and power terminal grounding Figure 16 Chassis Grounding and Power Terminal Grounding ...

Page 16: ...resistance requirement 5Ω The grounding part in the 5 08mm power terminal block is called surge grounding It is required to connect the chassis grounding part with the surge grounding part by an18 AWG yellow green line as seen below z 18 AWG yellow green line Unit mm Figure 17 18 AWG Yellow green Line Note IfKIEN1008G needs to do a dielectric voltage withstand test in order to ensure proper testin...

Page 17: ...rates abnormally Combo port SFP LEDs Speed Yellow ON 1000M working state i e 1000Base X OFF 100M working state i e 10 100Base FX or no connection Link Act Green ON Effective network connection in the port Blinking Network activities in the port OFF No effective network connection in the port Ethernet RJ45 port LEDs Each RJ45 Ethernet port has two indicators a yellow LED and a green LED The yellow ...

Page 18: ...08G 2GX GE 6GE 2 1000M Combos Ports 6 10 100 1000Base T X RJ45 Ports 12VDC 9 36VDC 24VAC DC 18 50VAC 18 72VDC dual redundant power inputs KIEN1008G 8GE 8 10 100 1000Base T X RJ45 Ports z The optional accessories of KIEN1008G are shown in Table 6 Table 6 KIEN1008G Optional Accessories Model Description DT BGAZ 02 Panel mounting kit DT FCZ RJ45 01 RJ45 dustproof shield 8 Basic Features and Specifica...

Page 19: ...2GX GE 6GE 8 5W full load KIEN1008G 8GE 7 5W full load z Physical Characteristics Housing Metal fanless Installation DIN Rail or Panel mounting Dimensions W H D 88mm 135mm 137mm Weight 0 76Kg z Environment Limits Operating Temperature 40 to 85 40 to 185 Storage Temperature 40 to 85 40 to 185 Ambient Relative Humidity 5 to 95 non condensing z MTBF 357000h z Warranty 5 years ...

Reviews: