background image

   

Appendix 

18

 

9 Appendix 

 

1. UL control number: 4SH7. 

2. The product identity: IND. CONT. EQ. FOR HAZ. LOC. Class I, Division 2, Groups A, B, C 

and D Hazardous Locations. 

3. Max Ambient temperature: xxxxxxxxxxxxxxxxxxxxxxxxxx 

Summary of Contents for KGW3102 Series

Page 1: ...KGW3102 KPS3102 Protocol Converter Hardware Installation Manual Publication Data Oct 2017 Version V1 0 ...

Page 2: ...updated as possible This document is not guaranteed to be error free and we reserve the right to amend it without notice to users All rights reserved No part of this documentation may be excerpted reproduced translated annotated or duplicated in any form or by any means without the prior written permission of KYLAND Corporation Copyright 2017 Kyland Technology Co Ltd ...

Page 3: ...rials on the device or cables Ensure adequate heat dissipation and tidy cable layout without knots Wear antistatic gloves or take other protective measures when operating the device Avoid any exposed metal wires because they may be oxidized or electrified Install the device in accordance with related national and local regulations Before power on make sure the power supply is within the allowed ra...

Page 4: ...ment damage or shell damage Equipment operation or performance has abnormally changed The equipment emits odor smoke or abnormal noise The device shall be installed in the appropriate enclosure if the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired The following information applies when operating this device in hazardous loca...

Page 5: ...deconnecter l equipement couper le courant ou s assurer que l emplacement est designe non dangereux La substitution de composants peut rendre ce materiel inacceptable pour les emplacements de Classe I Division 2 ...

Page 6: ...ed in inside of Enclosure or Equipment only 5 3 2 2 DIN Rail Dismounting 5 3 2 3 Mounting clearance 6 4 Connection 7 4 1 10 100Base T X Ethernet Port 7 4 2 RS 232 RS 422 RS 485 interface 8 4 3 Grounding 9 4 4 Power Terminal Block 9 4 5 DIP switch 11 5 Reset 13 6 LEDs 14 7 Access 15 7 1 Access through Telnet 15 7 2 Access through Web 15 8 Basic Features and Specifications 17 9 Appendix 18 ...

Page 7: ... They provide one 10 100Base T X Ethernet port and two RS 232 RS 422 RS 485 serial interface For details see the following table Table 1 Models Model KGW3102 1T2D L17 L17 KPS3102 1T2D L17 L17 Code definition Code option KGW KPS KGW Modbus gateway product model operating temperature 40 75 KPS Serial server product model operating temperature 40 75 Ports 1T2D Note one 10 100Base T X Ethernet port tw...

Page 8: ... and Interface Caution It is recommended to purchase the port dustproof shield optional to keep ports clean and ensure device performance 2 1 Front Panel Figure 1 Front Panel Table 2 Description of the Front Panel No Identifier Description ...

Page 9: ...d LED yellow 6 E1 10 100Base T X Ethernet port 7 Sn RS 232 RS 422 RS 485 Serial interface 8 Sn T Serial interface to send data indicator green 9 Sn R Serial interface to receive data indicator green Note In the above table the value of n is 1 2 for example S1 is the serial port 1 2 2 Top Panel Grounding screw Power terminal block DIP switch Reset button Figure 2 Top Panel ...

Page 10: ...ct and avoid covering the device housing when the device is running The figures in this manual are only for reference 3 2 Mounting Modes and Steps The series devicees support DIN rail mounting Before installation make sure that the following requirements are met 1 Environment temperature 40 to 75 ambient relative humidity 5 to 95 non condensing 2 Power requirement The power input is within the vol...

Page 11: ...ion dimensions 30mm 115mm 68mm Step 2 Insert the connecting seat onto the top of the DIN rail and push the bottom of the device inward and upward to ensure the DIN rail fits in the connecting seat Make sure the device is firmly installed on the DIN rail as shown in the following figure Figure 4 DIN Rail Mounting 3 2 2 DIN Rail Dismounting Step 1 As shown in the following figure press the device do...

Page 12: ...Mounting 6 Figure 5 DIN Rail Dismounting 3 2 3 Mounting clearance It is recommended that there should be enough clearance to install this product Top and bottom side 30mm Sides 20mm Front 30mm ...

Page 13: ...DI or MDI X connection automatically You can connect the port to a terminal or network device with a straight through or cross over cable Pin Definition Figure 6 RJ45 Port Table 3 Pin Definitions of 10 100Base T X Ethernet Port Pin MDI X Signal MDI Signal 1 Receive Data RD Transmit Data TD 2 Receive Data RD Transmit Data TD 3 Transmit Data TD Receive Data RD 6 Transmit Data TD Receive Data RD 4 5 ...

Page 14: ...ite 6 green 7 brown and white and 8 brown 4 2 RS 232 RS 422 RS 485 interface RS 232 RS 422 RS 485 interface using standard DB9 male interface RS 232 interface to support RTS CTS The serial interface pins supported by this device are defined in the following table Table 4 Serial interface pin definition Pin RS 232 RS 422 RS 485 1 CTS RxD B 2 RxD RxD A 3 TxD TxD Z Data B 4 RTS TxD Y Data A 5 GND GND...

Page 15: ...to the earth firmly Note Cross sectional area of the chassis grounding cable 2 5mm2 grounding resistance 5 4 4 Power Terminal Block There is a power terminal block on the rear panel of the device You need to connect the power wires to the terminal block to provide power to the device The device supports single PWR1 and redundant PWR1 and PWR2 power supply with a 4 pin 5 08mm spacing plug in termin...

Page 16: ...ing and Mounting Step 1 Ground the device properly according to section 4 3 Step 2 Remove the power terminal block from the device Step 3 Insert the power wires into the power terminal block according to Table 5 and secure the wires Step 4 Insert the terminal block with the connected wires into the terminal block socket on the device Step 5 Connect the other end of the power wires to the external ...

Page 17: ...e of the cable used on this device is 85 Warning Do not touch any exposed conducting wire terminal or component with a voltage warning sign because it may cause damage to humans Do not remove any part or plug in or out any connector when the device is powered on 4 5 DIP switch The top panel of the device has two DIP switches Each DIP switch has ON and OFF status The default configuration is OFF DI...

Page 18: ...nection 12 OFF Disable RS 485 terminal matching resistor for serial port S1 2 ON Enable RS 485 terminal matching resistor for serial port S2 OFF Disable RS 485 terminal matching resistor for serial port S2 ...

Page 19: ...t button on the top panel The button can be used to restore factory default settings You can restore factory default settings including the IP address by pressing and holding the button for five seconds The default IP address is E1 192 168 0 249 ...

Page 20: ...he CPU does not start up 10 100Base T X Ethernet port speed LED yellow On 100M working state 100Base TX Off 10M working state 10Base T or no connection 10 100Base T X Ethernet port connection status LED green On Effective port connection Blinking Ongoing network activities Off No effective port connection Sn T green Blinking Serial port n has a data signal sent Off Serial port n No data transfer S...

Page 21: ...port module is 192 168 0 249 default IP address of the device enter telnet 192 168 0 249 in the dialog box Figure 10 Access through Telnet Step 3 Click OK The Telnet CLI is displayed Then you can run the shell commands to perform operations 7 2 Access through Web Step 1 Connect the network port of a PC to the Ethernet port of the device with a network cable Step 2 Enter the IP address of the devic...

Page 22: ...Access 16 Note IE8 0 or a later version is recommended For details about how to access the device and other operations refer to the Web operation manual in the delivered CD ...

Page 23: ...wer Consumption Rated power consumption 1 8W Physical Characteristics Housing Metal fanless Protection class IP40 Exclude Terminal Block Installation DIN Rail mounting Dimensions W H D 30mm 115mm 68mm Weight 170g Environmental Limits Operating temperature 40 75 Storage temperature 40 85 Ambient relative humidity 5 95 non condensing Pollution degree 2 Insulation class 3 Autitude Up to 2000 m MTBF M...

Page 24: ...pendix 18 9 Appendix 1 UL control number 4SH7 2 The product identity IND CONT EQ FOR HAZ LOC Class I Division 2 Groups A B C and D Hazardous Locations 3 Max Ambient temperature xxxxxxxxxxxxxxxxxxxxxxxxxx ...

Page 25: ...78 Website http www kyland com Email support kyland com Address Building No 2 Shixing Avenue 30 shijingshan District Beijing China For more information about KYLAND products please visit our website http www kyland com ...