Chapter 2 - Technical Data
7
AMA 310/UMS V21.0
REALTIME ANALYZER
Measuring Bandwidth
0
–
120 dBµV
Resolution
0.1 dB
Measuring Accuracy
± 1.0 dB (at 20
°
C) warm up time > 5 min.
± 2.0 dB (0°C - 40°C) warm up time > 5 min.
Measuring Dynamics
70 dB
Measuring Bandwidth (RBW(-3 dB))
10 kHz
Span (Frequency Segment)
Total range
Real-time MAX Hold Function
PRBS
QAM Demodulator
Data
PRBS23
Symbol Rates
0.3
–
7.2 MSym/s
Modulation Schemes
QPSK, 16, 64 and 256 QAM
Measuring Parameters
(per ETR 290)
BER
1.00•10
-6
/ 1.00•10
-7
/
1.00•10
-8
depending on bandwidth / symbol rate
setting
MER up to 40 dB
Resolution 0.1 dB
Measuring Accuracy ± 1.5 dB
ASI
Output
Output level typ. 800 mV
pp
Connection BNC Socket
Output Impedance
75 Ohm
USB
Management
USB-A V1.1 (Full Speed)
Switch Control
USB-A KWS proprietary protocol and assignment;
Control output to optional cluster switch
SW 024
ETHERNET
Management (front panel)
RJ-45
10Base-T (10 MBit/s)
Streaming (rear panel)
RJ-45
10/100Base-T (100 MBit/s)
Protocol UDP / RTP