Possible cause
Remedy
The device is not working
- Control unit is not connected to the power supply
- connect control unit to power supply
- Power supply has failed
- check fuses in fuse box
- Plug adapter is not connected to microprocessor control system
- connect 2-pin plug to microprocessor control system
(15V
connection)
- Operating unit is not connected
- connect cable on operating unit to microprocessor
control system (TLI connection)
The water temperature is not as selected
- Hot and cold water inlet pipes switched
- swap connections
- Hot or cold water angle valve is closed or only partially open
- fully open both angle valves
- Hot or cold water pipe is blocked or bent
- rinse out pipes
- Boiler is empty or instantaneous water heater is not connected
- call manufacturer
- Temperature limits are set incorrectly
- apply the „Factory settings” option
(see operating instructions)
- Pressure difference between hot and cold water
- max. 0.5 bar permitted
inlet pipe is too great
0QYCVGTƃQY
- Angle valves are closed
- fully open both angle valves
- No water supply
- (e.g. no water pressure, main stopcock turned off)
- Control unit is not connected to the power supply
- connect control unit to power supply
- Power supply has failed
- check fuses in fuse box
- Plug adapter is not connected to microprocessor control system
- connect 2-pin plug to microprocessor control system
(15V
connection)
- Operating unit is not connected
- connect cable on operating unit to microprocessor
control system (TLI connection)
6JGƃQYQHYCVGTKUPQVCUUGNGEVGF
- Hot or cold water angle valve is closed or only partially open
- fully open both angle valves
- Hot or cold water pipe is blocked or bent
- rinse out pipes
-
5CXGFYCVGTNGXGNKPUWHƂEKGPV
CRRN[VJGd(CEVQT[UGVVKPIUqQRVKQP
(call
manufacturer)
9CVGTKUƃQYKPIEQPUVCPVN[
-
9CVGTKUƃQYKPIEQPUVCPVN[
ECNNOCPWHCEVWTGT
Water switches off automatically after a certain time
- Maximum on-time reached
- see operating instructions
-
+PFKXKFWCNN[UCXGFYCVGTNGXGNJCUDGGPTGCEJGF
RGTHQTOVJGdVKRnPnƃQYpHWPEVKQP
(call
manufacturer)
1RGTCVKPIWPKVƃCUJGUITGGPGXGT[UGEQPFU
- Cleaning mode is activated
- wait for 45 seconds or press the operating
unit for 5 seconds
Control unit is damp or wet inside
- Installed in incorrect location
- see label on the cover
- Pipes to the valves are not properly sealed
- call manufacturer
- Possible condensation on the valve housings
- no action needed
Operating unit (wired) is not responding
- Operating unit is connected incorrectly
- must be plugged in to TLI connection
- The operating unit is faulty
- call manufacturer
Summary of Contents for ONO touch light PRO 20.657.023.000
Page 26: ...802553 07 17 26 Notizen Note Nota Nota Notes ...
Page 28: ......
Page 32: ...4 21 654 010 Information Information Informazione Información Information J J ...
Page 33: ...5 21 654 020 Information Information Informazione Información Information J J ...
Page 34: ...6 21 654 030 Information Information Informazione Información Information J J ...
Page 38: ...10 Fertigmontageset Embellecedor Trim kit Inbus 2 0 mm 4 5 6 7 8 10 9 ...
Page 49: ...21 ...
Page 50: ...22 ...
Page 67: ...802550 03 17 15 4 Montage Montage Montagio QPVCLQ Installation 5 10 652 132 000 ...