Requirements
Requirements for Cat5/6/7 cables:
The pins are connected 1:1
Caution: the cable pairs must be twisted to EIA/TIA-568A (rare) or
EIA/TIA-568 B (common) pairs!
Erroneous assignments can not be found with a simple cable tester.
The pins for the green pair of wires are not adjacent to one other! The
cable must at the very least meet the Cat5 specifications and be suitable
for Gigabit transmission.
Applicable standards: Class D ISO/IEC 11801:2002 or EN 50173-
1:2002.
Schema EIA/TIA-568 B
Requirements fibre
Multi-Mode (standard)
Included with the MVX1-F is a LWL Multimode –
SFP Module which allows a transmission distance
of up to 500m.
Requires dedicated fibre connection, cable type
Duplex Multimode 50/125
µ
(OM2), LC connector
Single-Mode (optional)
LWL Singlemode – SFP Module up to 20km transmission distance
Requires dedicated fibre connection, cable type Duplex Singlemode, LC
connector
LWL Singlemode – SFP Modul BiDi up to 20km transmission distance
Requires dedicated fibre connection, cable type Singlemode, LC
connector
Pin
Color
1
Orange
/White
2
Orange
3
Green
/White
4
Blue
5
Blue
/White
6
Green
7
Brown
/White
8
Brown
Shielded installation cable with min.
cross section of 24AWG throughout the
length, shield is continguous and
connected to both ends.
Shielded patch cable is allowed for