5-2
A Guide to TracVision S3
5.3
Replaceable Parts
TracVision S3 has been designed with durability and low
maintenance in mind. If you experience an operating problem or
otherwise require technical assistance, contact your local
authorized TracVision S3 dealer/distributor first. Have the
Antenna Unit serial number ready with a list of the trouble
symptoms. If an authorized dealer/distributor is not located
nearby, contact the factory directly at the telephone, facsimile, or
e-mail listings inside the front cover.
Replacement part numbers for units that can be serviced in the
field are listed in Table 5-1. These parts may be obtained from
any KVH authorized dealer/distributor.
Part Name
Part Number
Baseplate Assembly
02-1044-02*
02-1044-04**
Radome Assembly
02-0953-05
Power Cable
32-0590-30
Antenna Data Cable
32-0630-30
RF Cable
32-0589-30
PC Cable
32-0628-06
CPU PCB
02-1043-02
RF PCB
02-1141-02
System Fuse
16-0017-3150
LNB (European System)
19-0196
LNB (N. American System)
19-0056
Switchplate
02-1023
* Baseplate assembly with single-output LNB
** Baseplate assembly with dual-output LNB
It is recommended that all other technical difficulties be resolved
by returning the TracVision S3 unit to an authorized service
provider.
Table 5-1
Field Replaceable Units
Should the fuse ever need to be
replaced, TracVision S3 uses
a 5x20mm, 3.15-amp, 250-volt fast-
blow fuse.
To help us continually improve the
quality and reliability of our
systems, please return any failed
component to KVH or KVH Europe
after you receive your replacement