33
|
41
RGBY Laser Projectors - v170120
Kvant Lasers s.r.o.
EN
4. Power up the system as normal.
5. Create a red beam effect (point) and check visually whether the red beam hits the exact centre of the bottom scanning
mirror. If not, use dichroic mounts DF1 to adjust the beam path accordingly (diagram below). To adjust the dichroic
mount use the two adjustment knobs – each works for one axis.
6. Create a cyan beam effect (point) and align the top of yellow beam to the top of blue beam at the dichroic filter DF4.
To adjust the yellow beam use dichroic mounts DF6.
7. Check visually whether the green beam hits the exact centre of the yellow beam at the dichroic filter DF4.
If not, use dichroic mounts DF5 to adjust the beam path accordingly.
8. Create a full size cyan circle (static tunnel effect) and check whether the green circle overlays the blue circle in all
points around the shape. If not, use dichroic mount DF4 to adjust the beam path accordingly.
9. Create a full size magenta circle (static tunnel effect) and check whether the red circle overlays the blue circle in all
points around the shape. If not, use dichroic mount DF3 and/or DF2 to adjust the beam path accordingly.
For control yellow laser module push
Colour balance display mode button
, or use Advanced mode in
Beyond. For more information see
chapter.
i