Troubleshooting Electrical Problems
979-2
63
STOP
Go to START
• Check for 110 VAC between #2 and #6. If there is voltage,
press the Start button. If no voltage, check the Stop button
to make sure it is all the way out and not stuck in, then check
the contact to make sure it is closed. If still no voltage, check
the wiring.
START
Go to 24VDC
• Push the Start button. If the Start light remains unlit, push
in the Start button and hold it in while a second person
checks for voltage between #2 and #7. If there is 110 VAC,
replace the ACR relay. If there is no voltage while the button
is held in, check the wiring.
24VDC
Home the
979-2
(see)
Check between DC+ and DC- for 24VDC. If no DC voltage, disconnect the
+ Brown/Red and - Blue/Black wires from the 24VDC power supply and
check for DC voltage where those wires were disconnected.
If no voltage:
• Check the input side for 110 VAC. If no 110 VAC, check the
fuse. If there is 110 VAC and no 24VDC, replace the 24VDC
Power Supply.
If there is 24VDC:
• Reconnect the + Brown/Red and - Blue/Black wires to the
24VDC power supply.
• Trace the + Brown/Red wire to the DC terminal block.
• Disconnect all brown wires from the + DC from the DC ter-
minal block except the + Brown/Red wire form the + 24VDC
power supply.
• Check for +24VDC at between any –DC and +DC terminal
on the DC Terminal block.
• Reinstall the + brown wires one by one checking for
+24VDC after installing each + brown wire. If at any point no
voltage is found trace the last reinstalled wire and check for
shorts.
Summary of Contents for 979-2
Page 1: ...979 2 Innovation Quality Honesty 979 2 Miter Trim Saw System Reference Published 4 24 07 ...
Page 2: ...979 2 ...
Page 4: ...b 979 2 ...
Page 8: ...f 979 2 ...
Page 10: ...Introduction 2 979 2 ...
Page 20: ...12 979 2 ...
Page 21: ...979 2 13 CHAPTER 2 Operation The following chapters explain normal operation of the 979 2 ...
Page 22: ...Operation 14 979 2 ...
Page 24: ...16 979 2 ...
Page 26: ...18 979 2 ...
Page 36: ...28 979 2 ...
Page 52: ...Maintenance 44 979 2 Grease Points Main Frame Bottom View Bottom View ...
Page 53: ...Lubrication Requirements 979 2 45 Fixed Head ...
Page 54: ...Maintenance 46 979 2 Movable Head Bottom View ...
Page 56: ...48 979 2 ...
Page 57: ...Cut Depth Set up 979 2 49 ...
Page 58: ...50 979 2 ...
Page 59: ...Cut Depth Set up 979 2 51 ...
Page 60: ...52 979 2 ...
Page 64: ...56 979 2 ...
Page 65: ...979 2 57 CHAPTER 5 Troubleshooting ...
Page 87: ...Touch Screen Troubleshooting 979 2 79 Technical Support Contact information ...
Page 92: ...84 979 2 ...
Page 98: ...90 979 2 ...
Page 100: ...92 979 2 ...
Page 102: ...94 979 2 ...