FEATURES

1) AC Mains Switch

The VHD 3200 has combination AC Mains switch/circuit breakers on the front panel.
If either of the switches shuts off during normal use, push it back to the ON position
once. If it will not stay on you should take the unit to qualified service personnel to
have it serviced.

2) Power On / Thermal

These are dual colour LED’s. When green they indicate that the Power Switch is On and
that channel of the amplifier is powered up. When red they indicate that that channel
has overheated and shut down. The unit will Auto Reset after it cools down to a safe
operating temperature.

3) Signal Present

These green LED’s indicate when signal is present at the Input to that particular channel
of the amplifier.

4) Limiter

These red LED’s indicate when the audio limiter has been activated for that particular
channel of the amplifier.

3

POWER ON /

 THERMAL (AUTO RESET)

SIGNAL PRESENT 

LIMITER

3.1 FRONT PANEL

1

2

3

4

Summary of Contents for VHD3200

Page 1: ...VERY HIGH DEFINITION VHD Active Driven Vertically Arrayable Long Throw Wide Dispersion Speaker System VHD 3200 OPERATOR S MANUAL ...

Page 2: ... the manufacturer 12 The unit is intended to use in a 19 rack Follow the mounting instructions When a rack on wheels is used use caution when moving the loaded rack to avoid injury from tipping over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Do not connect a VHD 3200 output in parallel or series with any other VHD 3200 s output Do not connect the VH...

Page 3: ... 1 Introduction 2 Getting Started 2 1 Unpacking 2 2 Rack Mounting 2 3 Cooling 2 4 AC Requirements 3 Features 3 1 Front panel 3 2 Rear panel 4 Operation 5 Specifications 6 Warranty Service Contact Information ...

Page 4: ...The unit acts as a slave for the VHD 2000 which provides audio and control signal It can also be used with the ERAK 2500R when used in combination with KV2 Audio ES systems and power the associated ES subwoofer systems Although this unit is simple to operate improper use can be dangerous This is a very high powered device that can put out high voltages and sizable currents Always use safe operatin...

Page 5: ...carton is unavailable contact your supplier to obtain a replacement The VHD 3200 carton should contain VHD 3200 amplifier control unit User s manual PowerCon detachable power cable 2 2 RACK MOUNTING VHD 3200 s will mount in standard 19 rack systems Integral rear mounting rack ears are also provided for additional support do not rely on fixing and mounting the VHD 3200 using just the front panel as...

Page 6: ...e doors or covers on the rear of the rack the exhaust air must flow without restriction If you are using racks with closed backs use fans on the rear rack panel to ensure an ample air supply 2 2 4 AC REQUIREMENTS Two PowerCon cables are provided to connect the VHD 3200 to a suitable AC power supply The PowerCon is a connector without breaking capacity i e the PowerCon should not be connected or di...

Page 7: ...hey indicate that the Power Switch is On and that channel of the amplifier is powered up When red they indicate that that channel has overheated and shut down The unit will Auto Reset after it cools down to a safe operating temperature 3 Signal Present These green LED s indicate when signal is present at the Input to that particular channel of the amplifier 4 Limiter These red LED s indicate when ...

Page 8: ...dard PowerCon terminated AC Mains cables 3 Fans The cooling fans operate continuously while the VHD 3200 is on An internal temperature sensor increases the speed of the fans during high temperature conditions Air enters through the front grille and exits through the rear Be sure to allow adequate air flow to the front of the rack in which the VHD 3200 is mounted 4 EP4 Connectors One for each chann...

Page 9: ...ing The various VHD2000 combinations are shown in the following table Please refer to the VHD 2000 or the ERAK 2500R manuals for further information on setting up these systems Amplifier Controller Setting VHD 2000 Setting 1 VHD 2000 Setting 2 VHD 2000 Setting 3 VHD 2000 Setting 4 VHD 2000 Setting 5 VHD 2000 Setting 6 Channel A 1 x VHD 2 15 2 x VHD 4 18 1 x VHD 2 15 1 x VHD 2 15 1 x VHD 2 15 1 x V...

Page 10: ...al breaker for AC Overload and Short Circuit Protection Amplifier Type High efficiency current enhancing Switch Mode technology with Active Filter Rated Continuous Power 1600 Watts Distortion 05 THD Operating Bandwidth 20Hz 1kHz Cooling Forced Cooling aluminium heat sink Two high capacity fans mechanically isolated electronic speed control Physical Height 7 00 177 8mm Width 19 00 483mm Depth 19 5 ...

Page 11: ...f the complexity of the design and the risk of electrical shock all repairs must be attempted only by qualified technical personnel If the unit needs to be shipped back to the factory it must be sent in its original carton If improperly packed the unit may be damaged To obtain service contact your nearest KV2 Audio Service Centre Distributor or Dealer CONTACT INFORMATION KV2 Audio International KV...