background image

IMPORTANT SAFETY INSTRUCTIONS

Before using your VHD 3200, be sure to carefully read the applicable items of these
operating instructions and the safety suggestions 

1. Keep this manual for future reference. 

2. Heed all warnings. 

3. Follow all instructions. 

4. Do not use this unit near water. Do not spill water or other liquids into or on the unit. Do not

operate the VHD 3200 while wet or standing in liquid. 

5. Clean only with dry cloth. 

6. Do not block the air intake or exhaust ports. Install the unit in accordance with the

instructions. 

7. Do not operate the VHD 3200 near heat producing devices such as radiators, heat registers,

stoves or other apparatus that produce heat. 

8. Always operate the unit with the chassis ground wire connected to the electrical safety earth.

Do not defeat the safety purpose of a grounding-type plug. A grounding type plug has two
pins and a third grounding prong. The third prong is provided for your safety. If the provided
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 

9. Connect only to AC power outlets rated 115-250V, 50-60Hz. 

10. Do not use this VHD 3200 if the power cable is broken or frayed. Protect the power cable

from being walked upon or pinched particularly at the plugs and the point where it exits from
the apparatus. 

11. Only use accessories specified by the manufacturer. 

12. The unit is intended to use in a 19” rack. Follow the mounting instructions. When a rack on

wheels is used, use caution when moving the loaded rack to avoid injury from tipping over. 

13. Unplug this apparatus during lightning storms or when unused for long periods of time. 

14. Do not connect a VHD 3200 output in parallel or series with any other VHD 3200’s output.

Do not connect the VHD 3200 output to any other voltage source, such as battery, mains
source, or power supply, regardless of whether the VHD 3200 is turned on or off. 

15. Do not run the output of any VHD 3200 back into another channel's input. 

16. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has

been damaged in any way such as: 

• Power-supply cord or plug is damaged 

• Liquid has been spilled into the unit 

• An object has fallen into the unit 

• The unit has been exposed to rain or moisture 

• The unit does not operate normally 

• The unit was dropped or the enclosure is damaged 

17. Do not remove top or bottom covers. Removal of the cover will expose hazardous voltages.

There are no serviceable parts inside and removal may void the warranty. 

18. An experienced user shall always supervise this professional audio equipment, especially if

inexperienced adults or minors are using the equipment.

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER.
NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.

WARNING:

To prevent fire or electric shock, do not expose this equipment to rain or moisture.

Summary of Contents for VHD3200

Page 1: ...VERY HIGH DEFINITION VHD Active Driven Vertically Arrayable Long Throw Wide Dispersion Speaker System VHD 3200 OPERATOR S MANUAL ...

Page 2: ... the manufacturer 12 The unit is intended to use in a 19 rack Follow the mounting instructions When a rack on wheels is used use caution when moving the loaded rack to avoid injury from tipping over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Do not connect a VHD 3200 output in parallel or series with any other VHD 3200 s output Do not connect the VH...

Page 3: ... 1 Introduction 2 Getting Started 2 1 Unpacking 2 2 Rack Mounting 2 3 Cooling 2 4 AC Requirements 3 Features 3 1 Front panel 3 2 Rear panel 4 Operation 5 Specifications 6 Warranty Service Contact Information ...

Page 4: ...The unit acts as a slave for the VHD 2000 which provides audio and control signal It can also be used with the ERAK 2500R when used in combination with KV2 Audio ES systems and power the associated ES subwoofer systems Although this unit is simple to operate improper use can be dangerous This is a very high powered device that can put out high voltages and sizable currents Always use safe operatin...

Page 5: ...carton is unavailable contact your supplier to obtain a replacement The VHD 3200 carton should contain VHD 3200 amplifier control unit User s manual PowerCon detachable power cable 2 2 RACK MOUNTING VHD 3200 s will mount in standard 19 rack systems Integral rear mounting rack ears are also provided for additional support do not rely on fixing and mounting the VHD 3200 using just the front panel as...

Page 6: ...e doors or covers on the rear of the rack the exhaust air must flow without restriction If you are using racks with closed backs use fans on the rear rack panel to ensure an ample air supply 2 2 4 AC REQUIREMENTS Two PowerCon cables are provided to connect the VHD 3200 to a suitable AC power supply The PowerCon is a connector without breaking capacity i e the PowerCon should not be connected or di...

Page 7: ...hey indicate that the Power Switch is On and that channel of the amplifier is powered up When red they indicate that that channel has overheated and shut down The unit will Auto Reset after it cools down to a safe operating temperature 3 Signal Present These green LED s indicate when signal is present at the Input to that particular channel of the amplifier 4 Limiter These red LED s indicate when ...

Page 8: ...dard PowerCon terminated AC Mains cables 3 Fans The cooling fans operate continuously while the VHD 3200 is on An internal temperature sensor increases the speed of the fans during high temperature conditions Air enters through the front grille and exits through the rear Be sure to allow adequate air flow to the front of the rack in which the VHD 3200 is mounted 4 EP4 Connectors One for each chann...

Page 9: ...ing The various VHD2000 combinations are shown in the following table Please refer to the VHD 2000 or the ERAK 2500R manuals for further information on setting up these systems Amplifier Controller Setting VHD 2000 Setting 1 VHD 2000 Setting 2 VHD 2000 Setting 3 VHD 2000 Setting 4 VHD 2000 Setting 5 VHD 2000 Setting 6 Channel A 1 x VHD 2 15 2 x VHD 4 18 1 x VHD 2 15 1 x VHD 2 15 1 x VHD 2 15 1 x V...

Page 10: ...al breaker for AC Overload and Short Circuit Protection Amplifier Type High efficiency current enhancing Switch Mode technology with Active Filter Rated Continuous Power 1600 Watts Distortion 05 THD Operating Bandwidth 20Hz 1kHz Cooling Forced Cooling aluminium heat sink Two high capacity fans mechanically isolated electronic speed control Physical Height 7 00 177 8mm Width 19 00 483mm Depth 19 5 ...

Page 11: ...f the complexity of the design and the risk of electrical shock all repairs must be attempted only by qualified technical personnel If the unit needs to be shipped back to the factory it must be sent in its original carton If improperly packed the unit may be damaged To obtain service contact your nearest KV2 Audio Service Centre Distributor or Dealer CONTACT INFORMATION KV2 Audio International KV...