14
15
When abnormality occurs during operation
Before requesting service
Before requesting service
Is the power cord plugged into
the outlet properly?
Are the Container and Noise Reduction
Cover perfectly combined to the Body?
If the product
does not operate
(common).
If ingredients are
not blended well.
If vacuuming
system does not
work properly.
Corrective measures
Checklist
Symptoms
Did you choose a menu item properly
according to the function of each
ingredient?
Did you put the proper amount of
ingredients specified in the manual?
- Plug the power cord into the outlet properly.
- Use after combining the Container and Anti-Noise
Cover to the Body perfectly.
- Use the right menu item according to the function
of each ingredient.
- Comply with the amounts of ingredients in the manual.
- After separating the Noise Reduction Cover, open
the Container Lid to mix ingredients thoroughly.
- Separate the Container from the Body and
mix ingredients well before re-operating.
4) If the Body moves a bit during operation
- Wipe any water, oil or dust on the Rubber Feet at the bottom of the Body or water on the table.
5) If the motor makes a smell during initial use
- During initial use, any products using motors may generate a little amount of smoke and smell due to the motor drying process.
- This will disappear naturally after a few times of use
6) If air continues to come up from inside the Container when performed in a Vacuum
- Stop the product, move ingredients to a plate, re-combine the Blade Assembly and operate the product again.
7) Vacuum Containers and Blade Sets are consumable parts, so please use them once every 6 months or
a year depending on the number of times you use.
If the motor power sensor detects
excessive ingredients for protect-
ing the motor.
If the motor temperature sensor
detects motor temperature rise.
Corrective measures
Symptoms
- Pull out the power plug.
- Re-operate the product by complying
with the standard amount by ingredient.
- Pull out the power plug.
- Cool off the Body for 30 minutes
before reusing.
Dial button(red) LED Flash/Buzz
Bee
~
- Assemble Vacuum Valve and Container Lid properly.
- Put Noise Reduction Cover on properly place.
1) If hearing abnormal noise
-
Check rotating condition (bearing) of the Container.
- After stopping the product, check if the Container and Noise Reduction Cover are properly combined.
- Check size and amount of an ingredient (Below 3cm).
2) If the motor does not rotate
- Check if the power cord is plugged into the outlet properly.
- Check if the Container and the Body are perfectly combined
3) If the motor stops during operation (it is for safety of motor, not failure or malfunction).
Vacuum Error
:
LED on the Dial Button flashes to
or The Button on the menu flashes
with a beep.
How to use (Optional) Blade wrench
- Putting the Noise Reduction Cover in water may
cause failure; this can be repaired by paid service.
- Clean the Body and Noise Reduction Cover with
dry cloth.
* If water permeate inside handle, remove rubber
pad to dry water, and then reassemble it.
- When cleaning the Container,
do not put the Blade Assembly in water.
(It may cause malfunction and rust. )
- Do not wash the container into the dishwasher.
- Putting the Blade Assembly in water may cause
failure; this can be repaired by paid service.
- Do not wash the container in hot water over
temperature 40
℃
(100
℉
)
Blade
Assembly
Cleaning and Care / How to use (Optional) Blade wrench
1) Separating Blade Assembly
- Put the "Blade Wrench" on the bottom part of the Container where the Blade Assembly is combined.
- Turn the Handle counterclockwise and remove the blade set by inserting a knife wrench vertically
into the container as shown in Figure 3.
2) Combining Blade Assembly
- Place the Blade Assembly on the bottom part of the Container.
- Put the "Blade Wrench" on the Blade Assembly and turn it clockwise.
(If the Blade Assembly is not perfectly combined, it does not become the Vacuum condition.)
②
②
③
③
①
①
Summary of Contents for SV-500
Page 10: ...18 ...