background image

Port-A-Cool, LLC • 709 Southview Circle • Center, TX  75935 

www.kuulaire.com • 1-888-999-6511

3

WARNINGS AND SAFETY RULES 

▲ 

LOCATION 

PARTS DESCRIPTION 

 

 

ELECTRICAL 

ASSEMBLY INSTRUCTIONS 

WARRANTY 

CLEANING AND MAINTENANCE 

TECHNICAL SPECIFICATIONS 

TROUBLESHOOTING 

REMOTE CONTROL 

USE AND OPERATION 

!

ON/OFF
1. Connect the cord to a power outlet.  Alternating 
amber/red pilot light will start flashing and the display 
is animated.  The unit is in STANDBY.
2. Press the ON/OFF button to turn the unit on. Indicator 
light will illuminate. To turn off, press
the POWER button again.
When the ON/OFF button is pressed, the cooler will start 
at level 2 speed (medium) then drops to level 1 speed 
(Low)

SPEED
Press the SPEED button to select the desired fan speed. 
The selected fan speed indicator LED light
will light up. Fan speed settings are 1( LOW) - 2 
(MEDIUM) - 3 (HIGH).

MODE:
Press the MODE button to select the desired fan mode. 
The selected fan mode indicator LED light
will light up. When SLEEP or NATURAL is selected, air 
speed will randomly vary.

COOL

To use the unit as an evaporative cooler, adjust the 
WATER FLOW CONTROL KNOB on the side
panel. Water will be pumped up to the water 
distributor compartment and start wetting out the 
cellulose cooling media in the rear of the unit. After 
approximately three minutes, as the pad becomes 
saturated, the air from the outlet should be cool. Turn 
the knob to OFF position when ‘Cool’ function is not 
desired.

SWING:
Press the SWING button to direct the air stream. The 
vertical louvers will begin to move automatically
from side to side. The indicator LED will come on. To 
adjust the vertical direction of air flow,
adjust the horizontal louvers manually.

TIMER
The unit comes with an 990 minutes timer. To set, press 
the TIMER button to the desired operation
time. The selected time will be displayed. When the 
pre-selected time has elapsed, the unit will
automatically shut off.

ION:
Press ION button once to start. LED light will 
illuminate. Unit will release negative ions for air
purifying function. Press again to stop the function.

WARNINGS AND SAFETY RULES 

▲ 

LOCATION 

PARTS DESCRIPTION 

 

 

ELECTRICAL 

ASSEMBLY INSTRUCTIONS 

WARRANTY 

CLEANING AND MAINTENANCE 

TECHNICAL SPECIFICATIONS 

TROUBLESHOOTING 

REMOTE CONTROL 

USE AND OPERATION 

!

ON/OFF – start or turn off the unit
Speed – 1 (Low)/2 (Medium)/3 (High)
Swing – automatic swing of louvers
Mode – Sleep/Natural/Normal
Timer – timer function up to 990 minutes

Summary of Contents for PACKA54

Page 1: ...PORTANT INSTRUCTIONS Read all instructions carefully before setting up and operating this unit This manual was designed to provide you with important information needed to setup operate maintain and trouble shoot your cooler Failure to follow these instructions may damage and or impair its operation and void the warranty Owner s Manual English Arabic ...

Page 2: ...rial 8 Do not operate the unit with a damaged power cord 9 Do not attempt to repair or adjust any electrical or mechanical functions of the unit 10 The PACKA54 unit should run on 110 120v 60 only and PACKA542205060 on 220 240V 50 60Hz AC only 11 Do not cover unit air inlet or air outlet openings 12 This product is not intended for use in wet or damp locations 13 When not in use drain the water fro...

Page 3: ...nt and start wetting out the cellulose cooling media in the rear of the unit After approximately three minutes as the pad becomes saturated the air from the outlet should be cool Turn the knob to OFF position when Cool function is not desired SWING Press the SWING button to direct the air stream The vertical louvers will begin to move automatically from side to side The indicator LED will come on ...

Page 4: ...with water and use it on the exterior of the unit to remove any dust or dirt Never use harsh detergents solvents and corrosive cleaners to clean the unit When not in use drain the water reservoir and store the unit in an area where it is dry and out of sunlight Maintenance Regular draining at least once each week will decrease the water mineral build up and extend the life of the rigid media pad A...

Page 5: ...h algae week of initial use If the unit is not new there may be an algae issue replace the pad and maintain regularly Water droplets coming Calcium saturated water Drain water deep clean and clean the media out of air outlet Clogged media Media may need to be replaced The unit will not respond Damaged PCB Try with remote control If the unit responds PCB board fasteners loose Moisture in PCB If nei...

Page 6: ...ol 4 F Filling the Reservoir 5 G Cleaning and Maintenance 6 H Technical Specifications 6 I Trouble Shooting 7 A PRODUCT INTRODUCTION KA54 Air cooler is our latest design with microcomputer control system It can lower outlet temperature freshen the air with equipped ion humidify the air through the principle of water evaporation and melting ice LED panel makes it luxurious and easy to use Also equi...

Page 7: ...ﺎرج ﻣﺪاﺧﻞ ﺑﺘﻐﻄﻴﺔ ﺗﻘﻢ ﻻ 12 اﻟﺮﻃﺒﺔ أو اﻟﻤﺒﺘﻠﺔ اﻷﻣﺎآﻦ ﻓﻲ اﻟﺠﻬﺎز هﺬا ﺑﺘﺸﻐﻴﻞ ﺗﻘﻢ ﻻ 13 ﺗﻔﺮﻳﻎ ﻳﺠﺐ اﻟﺠﻬﺎز ﺗﺸﻐﻴﻞ ﻋﺪم ﻋﻨﺪ ﺟﺎف ﻣﻜﺎن ﻓﻲ وﺣﻔﻈﻪ اﻟﻤﺎء ﻣﻦ اﻟﺨﺰان 14 ﺣﺼﻴﺮة أو ﺳﺠﺎدة ﺗﺤﺖ اﻟﻜﻬﺮﺑﺎﺋﻲ اﻟﺴﻠﻚ ﺑﺘﻮﺻﻴﻞ ﺗﻘﻢ ﻻ ﻗﺪ ﻣﻜﺎن أي ﻋﻦ ﺑﺈﺑﻌﺎدﻩ ﻗﻢ ﻓﻴﻪ ﻳﺤﺪث اﻟﺘﻌﺜﺮ اﻟﻌﺮﻗﻠﺔ أو 15 اﻟﺠﻬﺎز هﺬا ﻣﻊ وﺻﻼت ﺗﺴﺘﻌﻤﻞ ﻻ 16 ﻣﻨﻔﺎخ ﺗﻠﻒ إﻟﻰ ﻳﺆدي ﻗﺪ ذﻟﻚ ﻷن اﻟﻬﻮاء ﻣﻨﺎﻓﺬ إﻟﻰ ﺗﺪﺧﻞ ﻣﺎدة أي ﺗﺪع أو ﺗﺪﺧﻞ ﻻ اﻟﻀﻤﺎن ﻓﻴﻠﻐﻲ اﻟﻬﻮاء 17 اﻟﻤﺎء ﺧﺰان ﻟﺘﻌﺒﺌﺔ ﻓﻘﻂ...

Page 8: ...14 ﺧﻤﻮد 15 ﻣﺄﺧﺬ اﻟﻜﻬﺮﺑﺎﺋﻲ اﻟﺘﻴﺎر اﻟﺘﺤ زر ﻓﻲ ﻜﻢ ﺗﺪﻓﻖ اﻟ ﻤ ﺎء اﻟﺘﺸﻐﻴﻞ واﻹﻳﻘﺎف 1 اﻟﺘﻴﺎر ﺑﻤﺄﺧﺬ اﻟﺴﻠﻚ وﺻﻞ 2 إﺿﻐﻂ وا اﻹﻳﻘﺎف زر ﻟﺘﺸﻐﻴﻞ ﻟﺘﺸﻐﻴﻞ اﻟﺠﻬﺎز اﻟﺒﻴﺎن ﻟﻤﺒﺔ ﺳﺘﻀﻴﺊ اﻟﻤﺆﺷﺮ اﻟﺠﻬﺎز ﻹﻳﻘﺎف إ ﺿﻐﻂ أﺧﺮى ﻣﺮة اﻟﺰر ﻣﺘﻮﺳ اﻟﻮﺿﻊ ﻓﻲ ﻳﺸﺘﻐﻞ اﻟﻤﺒﺮد ﻓﺈن اﻟﺘﺸﻐﻴﻞ ﻋﻠﻰ اﻟﻀﻐﻂ ﻋﻨﺪ ﺑﻄﺊ ﺛﻢ ﻂ 3 9 ﻃﻮﻳﻠﺔ رﻗﺎﺋﻖ 10 ﻗﺼﻴﺮة رﻗﺎﺋﻖ 11 اﻟﺘﺤﻜﻢ ﻟﻮﺣﺔ ﻟﻮﺣ ـ اﻟﺘﺤﻜ ﺔ ـ ﻢ اﻻﺳﺘﻌﻤﺎل 7 8 9 10 11 12 13 14 15 2 ...

Page 9: ...ﻰ إﺿﻐﻂ ﻟﻠﻀﺒﻂ ﻮب اﻟﺸﺎﺷﺔ ﻋﻠﻰ اﻟﻮﻗﺖ ﺳﻴﻈﻬﺮ اﻟﻮﻗﺖ ﻳﻨﺘﻬﻲ ﻋﻨﺪﻣﺎ ً ﺎ ﺗﻠﻘﺎﺋﻴ اﻟﺠﻬﺎز ﺳﻴﺘﻮﻗﻒ اﻟﻤﺤﺪد اﻷﻳ ﻮ ن ﻟﺘﺒﺪأ أﻳﻮن زر ﻋﻠﻰ واﺣﺪة ﻣﺮة إﺿﻐﻂ هﺬﻩ ﻓﺘﻌﻤﻞ اﻟﻬﻮاء ﻓﻲ اﻟﺴﺎﻟﺒﺔ اﻷﻳﻮﻧﺎت ﻣﻦ آﺒﻴﺮة أﻋﺪاد ﺑﺘﺤﺮﻳﺮ اﻟﻤﺒﺮد ﺳﻴﻘﻮم اﻟﻤﺆﺷﺮ ﻟﻤﺒﺔ ﺳﺘﻀﻴﺊ اﻟﻬﻮاء ﺗﺠﺪﻳﺪ ﻋﻠﻰ اﻷﻳﻮﻧﺎت ﻣﺮة اﻟﺰر ﻋﻠﻰ إﺿﻐﻂ اﻟﻌﻤﻞ ﻋﻦ اﻟﻮﺿﻊ هﺬا ﻓﻴﺘﻮﻗﻒ اﻟﻤﺆﺷﺮ ﻟﻤﺒﺔ ﺳﺘﻨﻄﻔﺊ أﺧﺮى ﺑﻌﺪ ﻣﻦ اﻟﺘﺤﻜﻢ ﺟﻬﺎز آﻨﺘﺮول اﻟﺮﻳﻤﻮت وهﻮ اﻟﻮﻗﺖ ﺧﺼﻢ وﻇﻴﻔﺔ ﺑﻪ ﻟﻴﺲ أﻧﻪ ﻋﺪا ﻣﺎ اﻟﺘﺤﻜﻢ ﻟﻮﺣﺔ ﻧﻔﺲ ...

Page 10: ... ﺎء اﻟﻤﺎء ﻟﺘﺪﻓﻖ ﺑﻤﻨﻈﻢ ﺟﺎﻧﺒﻪ ﻓﻲ ﻣﺰود اﻟﺠﻬﺎز إن ﺗﺸﻐﻴﻞ أﻗﺼﻰ ﻧﻤﻂ ﻋﻠﻰ اﻟﻤﻨﻈﻢ ﺑﻮﺿﻊ واﻟﺘﺒﺮﻳﺪ اﻟﺮﻃﻮﺑﺔ ﻣﻌﺪل ﻓﻲ اﻟﺘﺤﻜﻢ ﻳﻤﻜﻨﻚ ﻳﺘﻴﺢ وهﺬا اﻟﺘﺒﺮﻳﺪ ﻣﻦ درﺟﺔ أﻗﺼﻰ ﻓﻴﻮﻓﺮ اﻟﻮﺳﺎﺋﺪ ﻋﻠﻰ ﻟﻠﻤﺎء آﺎﻣﻞ ﺗﺪﻓﻖ إﻳﻘﺎف ﻋﻠﻰ ﺑﺎﻟﻀﻐﻂ اﻟﻨﻤﻂ هﺬا ﻳﻮﻗﻒ واﻟﺼﻴﺎ اﻟﻨﻈـﺎﻓﺔ ﻧـﺔ ﺗﺤﺬﻳــﺮ ﻣﻨﻪ ﺗﻔﺮﻳﻐﻬﺎ أو ﺑﺎﻟﻤﺎء اﻟﺨﺰان ﺗﻌﺒﺌﺔ أو ﺗﺼﻠﻴﺤﻪ أو اﻟﺠﻬﺎز ﺗﺤﺮﻳﻚ ﻗﺒﻞ اﻟﺠﻬﺎز ﻋﻦ اﻟﺘﻴﺎر إﻓﺼﻞ اﻟﻨﻈـﺎﻓﺔ واﻷوﺳﺎخ اﻟﻐﺒﺎر ﻣﻦ ﻟﻠﺠﻬﺎز اﻟﺨﺎرﺟﻲ اﻟﺠﺰء ﻟﺘﻨﻈﻴﻒ ﺑﺎﻟﻤﺎء ﻧﻈﻴﻔﺔ ﻗﻄﻌﺔ ...

Page 11: ...اﻟﻌﺴﻠﻲ ﻟﻠﻘﺮص اﻟﻮﺳﻴﻄﺔ اﻟﻮﺳﺎﺋﺪ إﺧﺮاج اﻵن ﻳﻤﻜﻨﻚ اﻟﻘﺮص ووﺳﺎﺋﺪ اﻟﻐﺒﺎر ﻓﻠﺘﺮ ﻏﻄﺎء إﻏﺴﻞ ﻧﻈﻴﻒ ﻣﺎء ﻓﻲ اﻟﻌﺴﻠﻲ اﻟﻔﻨﻴﺔ اﻟﻤﻮاﺻﻔﺎت KA54 اﻟﻤﻮدﻳــــﻞ 220 ﻓﻮﻟﺖ اﻟﺠﻬــﺪ ﺗﻘﺪﻳـﺮ 50 60 هﺮﺗﺰ اﻟﺘﺮدد واط 150 اﻟﻄﺎﻗﺔ ﺗﻘﺪﻳﺮ 20 ﻟﺘﺮ اﻟﻤﺎء ﺧﺰان ﺳﻌﺔ 75 41 39 ﺳﻢ اﻷﺑﻌﺎد 12 آﺠـــــﻢ ﺻﺎﻓﻲ اﻟــــﻮزن Technical Specification Model KA54A Rating voltage 220V Frequency 50 60Hz Power Consumption 150W Water Tank Capacity 20 Liters Dimension...

Page 12: ... اﻟﺴﺒﺐ اﻷﻋﺮاض اﻟﺘﺼﻠﻴﺢ ﺑﺎﻟﻤﺄﺧﺬ اﻟﺘﻴﺎر ﺑﻤﺄﺧﺬ ﻣﻮﺻﻞ ﻏﻴﺮ اﻟﺴﻠﻚ اﻟﺴﻠﻚ ﺗﻮﺻﻴﻞ ﻣﻦ ﺗﺄآﺪ ﻟﻠﻬﻮاء ﺗﻔﺮﻳﻎ ﻻ ﺗﺸﻐﻴﻞ وﺿﻊ ﻓﻲ ﻟﻴﺴﺖ اﻟﻜﻬﺮﺑﺎء اﻟﻜﻬﺮﺑﺎء ﺷﻐﻞ اﻟﻜﻠﻮرة ﻣﺘﻌﺪد اﻟﻔﻴﻨﻴﻞ ﺛﻨﺎﺋﻲ PCB ﺗﺎ ﻟﻒ ﺑﻌﺪ ﻣﻦ ﻳﻨﻄﻔﺊ ﻻ اﻟﺠﻬﺎز اﻟﺘﺤﻜﻢ ﺟﻬﺎز اﺳﺘﻌﻤﺎل ﺣﺎول اﻟﺮﻳﻤﻮت 6 آﻨﺘﺮول اﻻﺳﺘﺠﺎﺑﺔ ﻣﺪى ﻟﺘﺮى ﺗﻌﻤﻞ ﻻ آﻨﺘﺮول اﻟﺮﻳﻤﻮت ﺑﻄﺎرﻳﺔ اﻟﺒﻄﺎرﻳﺔ إﻓﺤﺺ اﻟﻤﻨﻔﺎخ ﻋﻠﻰ اﻟﻜﺎﻟﺴﻴﻮم ﺗﺮاآﻢ ً ﺎ ﺻﻮﺗ ﻳﺼﺪر اﻟﺠﻬﺎز اﻟﻜﺎﻟﺴﻴﻮم ﺑﻘﺎﻳﺎ ﻣﻦ ً ﺎ ﻋﻤﻴﻘ ً ﺎ ﺗﻨﻈﻴﻔ اﻟﺠﻬﺎز ﻧﻈﻒ ﻓ اﻟﻤﺎء...

Reviews: