GCU-30 is a manual key start genset control and protection 
module suitable for most available genset on the market.   

System Protection 

Description of each protection, condition and manners

 :

 

●  High Engine Temperature Protection : 

  Failure confirmation delay

3sec

 

  Temperature Switch type

Normal Open NO.

 

●  Low Oil Pressure Protection : 

  Failure confirmation delay

3sec

 

  Oil Pressure Switch type

Normal Close NC.

 

●  Engine Over Speed Protection : 

  Failure confirmation delay

3sec

 

  50Hz

Activate @ 55Hz

60Hz

Activate @ 66Hz

 

●  User Define Protection : 

  Failure confirmation delay

2sec

 

  Input contact type

Normal Open NO.

 

● 

Charge Alternator Failure : 

  Failure confirmation delay

3sec

 

  Warning  activated  when  Charge  voltage  is  below  Battery 

5VDC 

Warning Icon Reference Table 

ICON 

DESCRIPTION 

ACTION 

 

Engine Running   

None 

 

Over-speed 

Shutdown 

 

Low Engine Oil Pressure 

Shutdown 

 

High Coolant 

Temperature 

Shutdown 

 

Spare Shutdown 

Shutdown 

 

Charge Alternator Failure   

Warning 

 
 
 
 

 
 
 

Rear Panel Layout 

 
 
 
 
 

 
 
 
 
 
 
 
 
 

Suggested Panel Opening

66

66 ± 0.5 mm 

System Setting 

GCU-30 is equipped with a 3P dip switch for system setting. 
User  should  select  the  correct  setting  to  comply  with  the 
system specification   

●  SW 1 AC Frequency ON 50Hz OFF 60Hz  

●  SW 2 Engine Stop Mode 
 

ON

Energized to Start    OFF

Energized to Stop

 

●  SW 3 Engine Stop Timer Delay 
 

ON

20 sec    OFF

10 sec

 

After  wiring  is  completed,  user  should  always  check  and 
adjust the system setting accordingly to prevent engine from 
failing to operate. 

Specification 

ITEM 

DESCRIPTION 

Rated DC Input Voltage 

9.0 to 36 V 

Rated AC Input Voltage 

5 ~ 300VAC 

AC Frequency 

50/60 Hz 

Engine Stop Signal Output 

1.2 Amp @ 12/24VDC 

Engine Start Signal Output 

1.2 Amp @ 12/24VDC 

Preheat Signal Output 

1.2 Amp @ 12/24VDC 

Charge Motor Excitation 
Signal Output 

12/24VDC 

Operation Temperature 

-20 

C to 

60 

Relative Humidity 

90% or Below 

Rated Dissipation 

Under 3W 

Weight 

101 g ± 2% 

 

 

 
 

 

 

Headquarters : 

No.3, Ln. 201, Qianfu St., Qianzhen Dist., Kaohsiung City 80664, Taiwan 

Tel :

 + 886-7-8121771

   

Fax :

 + 886-7-8121775

   

URL : 

http://www.kutai.com.tw 

 