ADVR-16-400HZ

 

P1

VR1

EXT. VR

Field

GEN

VR2

A1

A2

VS1

F+

P2

F-

K

VS2

L

R

T

N

S

Field

EXT. VR

VR1

P1

VR2

A2

A1

VS1

F-

P2 F+

L

VS2

K

GEN

T

N

S

R

EA16A

EA16A

 

EA16A

EXT. VR

K

A1

VR1 VR2

Field

P2

P1

VS1

F-

VS2

F+

A2

L

GEN

T

R

S

N

 

Figure 4

 

220V Connection 

GEN

EXT. VR

K

VR1 VR2

A1

F+

P2

P1

VS1

F-

VS2

A2

L

T

N

R

S

EA16A

Field

 

Figure 3

 

Paralleling Connection 

Figure 5

 

380 / 480V Connection 

 

Field

EXT. VR

EA16

VR2

VR1

A2

A1

F-

VS1

P1 P2 F+

L

VS2

K

GEN

T

N

S

R

Aux.

Winding
60~300v

 

 

Figure 6

 

Auxiliary Winding 

ADVR-16 

ADVR-16 

ADVR-16 

ADVR-16 

ADVR-16 

ADVR-16-400HZ 

 

ADVR-16-400HZ 

 

ADVR-16-400HZ 

 

ADVR-16-400HZ 

 

ADVR-16-400HZ 

 

Summary of Contents for ADVR-16-400HZ

Page 1: ...ters No 3 Ln 201 Qianfu St Qianzhen Dist Kaohsiung City 80664 Taiwan ADVR 16 400HZ Universal Hybrid Analog Digital Voltage Regulator Operation Manual Universal 400Hz Intermediate Frequency 16 Amp Half Wave Self Excited Generator Automatic Voltage Regulator For Aviation and Military Spec 400Hz Generators ...

Page 2: ... Input Voltage 170 510 Vac 1 phase 2 wire CT 1A or 5A greater than 5VA DIP switch setting Frequency 50 60 Hz DIP switch setting Sensitivity 7 PF 0 5 Power Input Analogue Voltage Input Voltage 60 300 Vac 1 phase 2 wires Max 5 Vdc 10 3 Vdc Excitation Output Under Frequency Protection Factory Presets 240V 1 phase Continuous 63 Vdc 16A 50 60 Hz DIP switch setting Max 90 Vdc 20A for 10 secs Resistance ...

Page 3: ...ect switch K or L pending on the secondary current of the CT that you are using Voltage droop works when the CT and the AVR senses that the output of the generator voltage and current waveforms are out of synch and the AVR droops the output voltage of the generator to correct it 4 3 STAB If the generator output voltage oscillate adjusting the STAB potentiometer will stabilize the output voltage ov...

Page 4: ...n is not required the user can disable this function by switching DIP switch SW4 to ON position vice versa SECTION 5 NOTICE OF USE 5 1 Installation Notice Refer to Figure 2 and 4 5 1 1 Only a trained professional can Installation calibrate and inspections this AVR 5 1 2 Install this AVR inside the generator enclosure away from moisture corrosion and from any easy to reach area 5 2 Generator Operat...

Page 5: ... EA16A EXT VR K A1 VR1 VR2 Field P2 P1 VS1 F VS2 F A2 L GEN T R S N Figure 4 220V Connection GEN EXT VR K VR1 VR2 A1 F P2 P1 VS1 F VS2 A2 L T N R S EA16A Field Figure 3 Paralleling Connection Figure 5 380 480V Connection Field EXT VR EA16 VR2 VR1 A2 A1 F VS1 P1 P2 F L VS2 K GEN T N S R Aux Winding 60 300v Figure 6 Auxiliary Winding ADVR 16 ADVR 16 ADVR 16 ADVR 16 ADVR 16 ADVR 16 400HZ ADVR 16 400H...

Page 6: ...r adjustment is made Read start procedure carefully and adjust again U F protection activated Increase generator speed U F activated Incorrect voltage selection Read user s manual to select correct voltage Over output voltage Poor adjustment is made Read start procedure carefully and adjust again Incorrect voltage selection Read user s manual to select correct voltage Output voltage unstable Hunti...