INSTRUCTION MANUAL

TEL: in NY 631-567-0314                   TOLL FREE: 800-346-0857                FAX: 631-567-5826

1 YEAR WARRANTY

BOOK# 091-9-090 inst.book

Aug. 3, 2005

KUSSMAUL ELECTRONICS CO., INC

.

170 CHERRY AVE., WEST SAYVILLE, N.Y. 11796

AUTO DRAIN ACHP

AN AUTOMATIC MOISTURE DRAIN

FOR THE 091-9HP AIR COMPRESSOR

MODEL #091-9-090

INPUT :120 Volt, AC Solenoid

Summary of Contents for 091-9-090

Page 1: ...6 0857 FAX 631 567 5826 1 YEAR WARRANTY BOOK 091 9 090 inst book Aug 3 2005 KUSSMAUL ELECTRONICS CO INC 170 CHERRY AVE WEST SAYVILLE N Y 11796 AUTO DRAIN ACHP AN AUTOMATIC MOISTURE DRAIN FOR THE 091 9HP AIR COMPRESSOR MODEL 091 9 090 INPUT 120 Volt AC Solenoid ...

Page 2: ...own to seal off the vehicles air pressure when the bleed valve opens ITEM QUANTITY PARTNUMBER DESCRIPTION 1 1 A2231 1 C108 Solenoid Valve 120 Volt A C normally open 2 1 F5044 02 DH Z310 Filter with metal bowl 3 1 216P 2 Nipple 1 8 NPT 4 2 PLB112 4 Nipple 1 4 NPT Close 5 1 219 P 2 Plug 1 8 NPT 6 1 219 P 4 Plug 1 4 NPT 7 1 PL1 4 NIU Elbow 1 8 NPT male 1 4 tube 8 2 1202P4 4 Street Elbow 1 4 NPT 9 1 C...

Page 3: ...091 9 090 AUTO DRAIN ACHP INSTALLED ON 091 9HP AUTO PUMP ...

Page 4: ...to output terminals of pressure switch These are the same terminals that supply power to the AUTO PUMP motor 3 The AUTO DRAIN is now properly connected Test by bleeding system pressure to start AUTO PUMP and note that when pump shuts down air and moisture will bleed out of drain tube 4 Position drain tube to direct moisture to exterior of vehicle AUTO DRAIN WIRING INSTALLATION ...

Page 5: ... within 1 year from the date the equipment was shipped Equipment is to be returned shipping charges prepaid and will be returned after repair shipping charges paid Kussmaul Electronics Company Inc shall have no liability for damages of any kind to associated equipment arising from the installation and or use of the Kussmaul Electronics Company Inc products The purchaser by the acceptance of the eq...