SPECIFICATIONS

Input Power: 

120 Volt, 50/60 Hz, 3.5 Amperes

Input Fuse

:  6 ampere, fast blow

Output Power - Bat 1 & Bat 2: 

12 Volts DC, 15 Amperes Max, Total Output

Output Power - Battery Saver: 

12 Volts DC, 3 Amperes Max

Remote Sensing: 

Electronic, sense wires not required

LED Status Indicators: 

Power

: Red LED, Indicates 120 Volt AC power applied

Battery Saver Overload

: Yellow LED, Flashing, Indicates Battery Saver load greater than 3 amps

Charger Indicator: 

Remote Dual Bar Graph Display

Output Waterproof Circuit Breaker (Optional)

:  Bat 1  & Bat 2 - 30 Amperes, P/N: 090-0030-0

Output Buss Bar (Optional)

: 5 Studs, P/N: 002-3595-5

Weight: 

16 pounds 

OUTLINE DRAWING

170 Cherry Avenue

West Sayville, NY 11796

www.kussmaul.com

Ph: 800-346-0857

Fax: 631-567-5826

[email protected]

7

Summary of Contents for 091-39-12

Page 1: ...RY CHARGER scan using your mobile device for more information INSTRUCTION MANUAL INPUT 120 Volt 50 60 Hz 3 5 Amps OUTPUT BATTERY 1 2 15 Amps OUTPUT BATTERY SAVER 3 Amps 3 YEAR WARRANTY MODEL 091 39 12 170 Cherry Avenue West Sayville NY 11796 www kussmaul com Ph 800 346 0857 Fax 631 567 5826 sales kussmaul com ...

Page 2: ...ger from the AC source before attempting any maintenance or cleaning 7 LOCATION OF CHARGER The charger should be mounted on a wall vehicle floor ventilated compart ment or other suitable surface as close to the batteries to be charged as possible Do not block the char ger s fan or air intakes Do not mount the charger directly over the batteries as fumes may cause exces sive corrosion The area shou...

Page 3: ...pendently charged while maintaining battery isolation Each battery voltage is remotely sensed electronically eliminating the need for four sense wires Each of the charge controls is com pletely automatic and stops charging the battery when it is fully charged There is no trickle charge and therefore no danger of overcharging and water boil off III AUTOMATIC CURRENT LIMITING The charger contains au...

Page 4: ...tely 17 volts This voltage may be too high for the component connected It is suggested that the installer check the output of the battery saver when operating with A C In put and determine as each load is connected that the voltage does not rise Any load that creates an increase in voltage should not be connected to the battery saver but rather be connected directly to the battery VI REMOTE BATTER...

Page 5: ...ut terminal 4 Apply AC power shoreline power to input terminal and observe that the charger is operating 5 Verify that the battery voltage appears at the charger output terminals II WIRING SPECIFICATIONS 170 Cherry Avenue West Sayville NY 11796 www kussmaul com Ph 800 346 0857 Fax 631 567 5826 sales kussmaul com 5 Length of Wire to Battery feet Battery Charger Connections COM V BAT 1 V BAT 2 B S C...

Page 6: ...INSTALLATION WIRING DIAGRAM I WIRING DIAGRAM IS FOR A 10 FOOT INSTALLATION 6 ...

Page 7: ...icators Power Red LED Indicates 120 Volt AC power applied Battery Saver Overload Yellow LED Flashing Indicates Battery Saver load greater than 3 amps Charger Indicator Remote Dual Bar Graph Display Output Waterproof Circuit Breaker Optional Bat 1 Bat 2 30 Amperes P N 090 0030 0 Output Buss Bar Optional 5 Studs P N 002 3595 5 Weight 16 pounds OUTLINE DRAWING 170 Cherry Avenue West Sayville NY 11796...

Page 8: ...aterial or defects which become apparent in normal use within 3 years from the date the equipment was shipped Equipment is to be returned shipping charges prepaid and will be returned after repair shipping charges paid Kussmaul Electronics Company Inc shall have no liability for damages of any kind to associated equipment arising from the installation and or use of the Kuss maul Electronics Compan...

Reviews: