Kusam-meco KM 5040-T Operation Manual Download Page 15

®

®

27

28

WARRANTY

Each “KUSAM-MECO” product is warranted to be free from defects in 
material and workmanship under normal use & service.  The warranty 
period is one year (12 months) and begins from the date of despatch 
of goods.  In case any defect occurs in functioning of the instrument, 
under proper use, within the warranty period, the same will be rectified
by  us  free  of  charges,  provided  the  to  and  fro  freight  charges 
are borne by you.

THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY  &
IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, 
INCLUDING  BUT  NOT  LIMITED  TO ANY  IMPLIED  WARRANTY  OF 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
“KUSAM-MECO”  SHALL  NOT  BE  LIABLE  FOR  ANY  SPECIAL, 
INDIRECT,  INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES  OR 
LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE
WHATSOEVER.

This warranty extends only to the original buyer or end-user customer 
of a “KUSAM-MECO” authorized dealer.

This warranty does  not  apply  for  damaged  Ic’s, fuses, burnt PCB's, 
disposable  batteries,  carrying  case,  test  leads,  or  to  any  product 
which  in  “KUSAM-MECO’s”  opinion,  has  been  misused,  altered, 
neglected,  contaminated  or  damaged  by  accident  or  abnormal 
conditions of operation or handling.

“KUSAM-MECO” authorized dealer shall extend this warranty on new 
and unused products to end-user customers only but have no authority
to extend a greater or different warranty on behalf of “KUSAM-MECO”.

“KUSAM-MECO’s”  warranty  obligation  is  limited,  at  option,  free  of 
charge repair, or replacement of a defective product which is returned 
to  a  “KUSAM-MECO”  authorized  service  center  within  the  warranty 
period.

All transaction are subject to Mumbai Jurisdiction.

MUMBAI

TEST CERTIFICATE

AC TRMS DIGITAL CLAMPMETER

This Test Certificate warrantees that the product has been 

inspected  and  tested  in  accordance  with  the  published 

specifications.

The instrument has been calibrated by using equipment which 

has already been calibrated to standards traceable to national 

standards.

MODEL NO. _____________

KM 5040-T

SERIAL NO. ___________

DATE: ___________

ISO 9001

REGISTERED

QC

PASS

KUSAM-MECO

Summary of Contents for KM 5040-T

Page 1: ...l Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproof Pen Testers Solar Power Meter EMF Detector Wood...

Page 2: ...0 1 Measurement Category TAKE MEASUREMENT CAREFULLY AND YOU LL SPARE YOUR METER AND YOURSELF SOME PAIN Nearly every electrical engineer has a hand held digital multimeter DMM We sometimes take them fo...

Page 3: ...r the circuit being tested while power is applied to the circuit being measured Keep your fingers behind the finger guards of the test leads during measurement Inspect test leads connectors probes for...

Page 4: ...Approx 430gm with holster OPTIONAL ACCESSORIES BRUA 85Xa PC interface Kit BC 85Xa RS232 optical adapter cable Software CD BUA 2303 USB to Serial adaptor Bkb32 banana plugs to K type socket plug adapto...

Page 5: ...000 V 40Hz 500Hz 50 00 mV 500 0 mV 5 000 V 50 00 V 500 0 V 1000 V 0 5 rdg 3dgts 0 8 rdg 3dgts 1 0 rdg 4dgts 1 2 rdg 4dgts 10 mV 100 mV 1 mV 10 mV 100 mV 1 V Range Accuracy Resolution 10 mV 100 mV 1 mV...

Page 6: ...ough setting time for a significant change of ambient temperature It can take upto an hour for changes 5 C Supplied Thermocouple suitable for measurement upto 250 C 50 C 1000 C 0 3 rdg 3dgts 0 3 rdg 5...

Page 7: ...4dgts 0 15mV mA 3 3mV mA 3 3mV mA 45mV A 45mV A 0 1 mA 1 mA 0 01 mA 0 1 mA 0 001 A 0 01 A Range Burden Voltage Accuracy Resolution 10A continuous 10A To 20A for 30 seconds max with 5 minutes cool dow...

Page 8: ...ifferent scaling factors relating average to RMS values Average sensing RMS calibrated True RMS is a term which identifies a DMM that responds accurately to the effective RMS value regardless of the w...

Page 9: ...of a True RMS DMM A pure sinusoidal waveform has a Crest Factor of 1 4 A badly distorted sinusoidal waveform normally has a much higher Crest Factor NMRR is the DMM s ability to reject unwanted AC noi...

Page 10: ...u can also press the RANGE button momentarily to select another trigger level manually If the Hz reading becomes unstable select lower sensitivity to avoid electrical noise If the reading shows zero s...

Page 11: ...nctions Default at W Press SELECT button momentarily to select Continuity function that is convenient for checking wiring connections and operation of switches A continuous beep tone indicates a compl...

Page 12: ...after 30 seconds to extend battery life The instrument equips with an optical isolated interface port at the meter back for data communication Optional purchase PC interface kit BRUA 85Xa BC 85Xa RS2...

Page 13: ...nction like voltage function is selected 5 MAINTENANCE WARNING To avoid electrical shock disconnect the meter from any circuit remove the test leads from the input jacks and turn OFF the meter before...

Page 14: ...yed while powering on the meter is re organizing internal parameters Do not switch off the meter then and it will be back to normal measurement shortly However if self diagnostic message C_Er is being...

Page 15: ...ply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused altered neglected contaminated or damaged by accid...