3) SPECIFICATIONS :
GENERAL SPECIFICATIONS :
SPECIAL FEATURES:
Extended >1000 ~ 1500V DC range suitable for solar
TM
AutoCheck Voltage & Ohms
VFD-V & VFD-Hz function
5ms CREST-MAX capture mode (Peak Hold)
Autoranging Relative -Zero mode
Display Hold function &
EF-Detection (NCV)
Backlight LCD Display
Auto Power Off
Diode Test & Continuity Test
PC Interface (Optional)
Sensing :
TRMS sensing
Jaw Opening :
55mm max.
Display :
3-5/6 digits 6000 counts & 3½ digits 1,999 counts for Hz.
Update Rate :
5 per second nominal
Polarity :
Automatic
Low Battery :
Below approx 2.4V
o
o
Operating Temperature :
0 C to 40 C
Relative Humidity :
Maximum 80% R. H. for temperature upto
o
o
31 C decreasing linearly to 50% Relative Humidity at 40 C
o
o
Storage Temperature :
-20 C to 60 C, < 80% R.H.
(With battery removed)
Altitude :
Operating below 2000m
Temperature Coefficient :
nominal 0.15 x (specified accuracy) /
o
o
o
o
°C @ (0 C--18 C or 28 C--40 C), or otherwise specified
- 04 -
The instruments conform to CENELEC Low-Voltage directive
2006/95/EC and Electromagnetic compatibility directive
2004/108/EC.
Caution ! Refer to the explanation in this Manual
Caution ! Risk of electric shock
Earth (Ground)
Double Insulation or Reinforced insulation
Fuse
AC--Alternating Current
DC--Direct Current
Application around and removal from hazardous live
conductors is permitted
2) CENELEC Directives
INTERNATIONAL ELECTRICAL SYMBOLS
- 03 -