thank you for purchasing a sealey product. manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  safety

1.1.          

Personal PreCautions

 

9

   When using this meter, please observe all normal safety rules concerning:

   

Protection against the dangers of electric current.

   

Protection of the meter against misuse.

 

9

   Full compliance with safety standards can only be guaranteed if used with the test leads supplied. Failure to do so will invalidate the   

 warranty.

 

8

  

do not

 use leads if damaged or if the wire is bared in any way. 

1.2.   

general safety instruCtions

 

9

   Familiarise yourself with the applications, limitations and hazards of the meter.

 

If in any doubt consult a qualified electrician.

 

9

   When the meter is linked to a measurement circuit, 

do not

 touch unused meter terminals.

 

9

   When the scale of the value to be measured is unknown set the selector to the highest range available.

 

9

   Before rotating the range selector to change functions, disconnect test leads from the circuit under test.

 

‰

  

Warning! 

never perform resistance measurements on live circuits.

 

9

   Always be careful when working with multimeter. Keep your fingers behind the probe guards while measuring.

 

9

   When not in use, store the meter carefully in a safe, dry, childproof location. Storage temperature range -10°C to 50°C

 

8

  

do not

 apply voltage or current to the meter that exceeds the specified maximum.

 

9

   The user shall ensure that test probes are correctly selected in order to prevent danger. Probes shall be selected to ensure that  

 

  adequate barriers guard against inadvertent hand contact with live conductors under test and that probes have minimal exposed  

       

  probe tips.  Where there is a risk of the probe tip short circuiting with other live conductors under test, it is recommended that the    

  exposed tip length shall not exceed 4mm.  

2.  introduCtion

lightweight, auto-ranging digital multimeter with double moulded plastic housing and a 2000 counts lCd display. Features forward facing work 

light, data hold and non-contact AC voltage detection. Conforms to en 61010-1 CATIII 1000V / CAT IV 600V safety standard.

measures: AC and dC Voltage,  AC and dC Current, Resistance, diode Test, Continuity Test.

3.  sPeCifiCation

model no   ...............................................................................................................................................mm102

AC Voltage (Accuracy) ...............................................................................2V, 20V (±1%), 200V, 600V (±2.3%)

dC Voltage (Accuracy) ...............................................................200mV (±0.5%), 2V, 20V, 200V, 600V (±1.2%)

AC Current (Accuracy) ........................................................................200µA,  2000µA, 20mA, 200mA (±2.5%)

dC Current (Accuracy)........................................................................... 200µA,  2000µA, 20mA, 200mA (±2%)

Resistance (Accuracy)

.........................200Ω.(±0.8%),.2KΩ,.20KΩ,.200KΩ.(±1.2%),.2MΩ.(±5%),.20MΩ.(±10%)

Capacitance (Accuracy).................................................................................................................................no

Frequency (Accuracy). ...................................................................................................................................no

duty Cycle ......................................................................................................................................................no

Continuity Audible ................................................  ........................................................................................Yes

diode Test .....................................................................................................................................  ...............Yes 

Transistor Test ...............................................................................................................................................no

Hi- Impact Case .............................................................................................................................................no

digits x Height.....................................................................................................................................4 x 14mm

low Battery Indicator ....................................................................................................................................Yes

Batteries (supplied) .........................................................................................................................  2  AAAx1.5V

Size (l x W x d) ......................................................................................................................105 x 57 x 34mm

Weight ........................................................................................................................................................160g

Conformity ........................................................................................................................................en61010-1