background image

An ISO 9001:2008  Company

®

G-17, Bharat  Industrial  Estate,  T. J.  Road,  Sewree (W),  Mumbai -  400 015. INDIA.

Sales Direct.:

 022 -24156638,     

Tel. : 

022-241224540, 24181649,      

Fax : 

022 - 24149659

Email :

 [email protected],                                        

Website :

 www.kusamelectrical.com

An ISO 9001:2008  Company

®

All Specifications are subject to change without prior notice

Chhaya Computer/D:/Chhaya/Coreldraw Files/New catlogs Dec 2011/KM 2720-KM 2725.cdr

3¾ DIGITS AC/DC AUTORANGING 

DIGITAL CLAMPMETER

Model - KM 2720 - 17 FUNCTIONS  27 RANGES

              KM 2725 - 17 FUNCTIONS  27 RANGES 

KM2720

KM2725

SPECIAL FEATURES :

?

   High Resolution DCA / ACA of 1mA             

?

   Auto Polarity display

?

   Auto Zero Adjustment                                   

?

   Display annunciators for all functions &  ranges

?

   Continuity & Diode Measurements               

?

   Auto Power Off

?

   Low Battery Indication

ACCESSORIES :

 

Test leads, Carrying Case, Battery installed,  User's  Manual

ï

 Sensing : 

 Average sensing

ï

 Jaw Size :

 23 mm

ï

 Display : 

 3¾ digits 4000 counts LCD display   

ï

 Sampling rate :

 2.5 reading / sec.

ï

 Low Battery :

 “      ” mark is displayed when 

     the Battery Voltage drops below 2.4V

ï

 Over range indication :

 Display “OL” or  “-OL”

GENERAL SPECIFICATIONS :

ï

 Operating Temperature : 

0°C~50°C;    

£

 

75% R.H.

ï

 Storage Temperature : 

-20°C

 

 to 60°C; 

£

 80% R.H. 

      (Without battery)

ï

 Power Supply :

 1.5V AAA  battery x 2

ï

 Dimension :

 183(L) X 43(W) X 31(H) mm

ï

 Weight : 

Approx. 200

 

gm (battery included)

ELECTRICAL  SPECIFICATIONS- KM2720 / KM2725

Accuracy is ± (% reading number of digits ) or otherwise specified, at 23°C ± 5°C & less than 75% R.H. 

400    

W

100 m

W

4      k

W

1        

W

40    k

W

10      

W

400  k

W

100    

W

RESISTANCE

±(1.0%rdg + 2dgts)

Accuracy

Overload Protection :

 250V rms

Range

Resolution

1      k

W

4     M

W

40   M

W

10    k

W

±(1.0%rdg + 2dgts)

±(1.0%rdg + 2dgts)

±(1.0%rdg + 2dgts)

±(1.0%rdg + 2dgts)

±(1.5%rdg + 2dgts)

Range

DIODE TEST

Description

Display read approx. Forward 
Voltage of diode. 
Accuracy : ±(3.0%rdg + 3dgts)

 

Range

CONTINUITY TEST

If the resistance is less than 
100

W

, the beeper sounds 

continuously

Description

Range

40   A

10   mA

±(2.0%rdg + 3dgts)

200 A

100 mA

±(2.5%rdg + 3dgts)

AC/DC CURRENT (Model KM 2720)

Accuracy (ACA)

Resolution

±(2.0%rdg + 2dgts)

±(2.5%rdg + 2dgts)

Accuracy (DCA)

AC/DC CURRENT (Model KM 2725)

±(3.0%rdg + 3dgts)

±(2.0%rdg + 3dgts)

Accuracy (ACA)

1    mA

10  mA

Resolution

Range

4    A

40  A

±(3.0%rdg + 2dgts)

±(2.0%rdg ± 2dgts)

Accuracy (DCA)

Range

40   nF

10    pF

±(2.5%rdg + 10dgts)

400 nF

100  pF

±(2.0%rdg + 4dgts)

CAPACITANCE

Accuracy

Resolution

4     

m

F

40   

m

F

1      nF

10    nF

±(2.0%rdg + 4dgts)

±(2.5%rdg + 4dgts)

Overload Protection :

 250V rms

400 mV

100  

m

V

4        V

1     mV

40      V

10   mV

400    V

100 mV

AC VOLTAGE

±(1.8%rdg + 5dgts)

±(1.5%rdg + 3dgts)

Accuracy

Input Impedance :

    10M

W

AC Voltage Test Frequency :

 50Hz~500Hz for 400V &  below, 

& 50Hz~100Hz for above 400V.

Overload Protection :

 DC 1000V or AC 750V rms

Range

Resolution

750    V

1        V

±(1.0%rdg + 3dgts)

±(1.0%rdg + 3dgts)

±(1.0%rdg + 3dgts)

400 mV

100  

m

V

4        V

1     mV

40      V

10   mV

400    V

100 mV

DC VOLTAGE

±(1.0%rdg + 2dgts)

Accuracy

Input Impedance :

    10M

W

Overload Protection :

 DC 1000V or AC 750V rms

Range

Resolution

1000    V

1        V

±(0.8%rdg + 2dgts)

±(0.8%rdg + 2dgts)

±(0.8%rdg + 2dgts)

±(0.8%rdg + 2dgts)

Range

9.999 Hz

Unspecified

99.99 Hz ~ 9.999 MHz

FREQUENCY

Accuracy

±(0.2%rdg + 3dgts)

Sensitivity :

 Frequency - 0.7V AC rms;  

                     Voltage - 0.1V AC rms

Overload Protection :

 250V rms

Range

DUTY CYCLE

Sensitivity

Resolution

0.1%~99.9%

Overload Protection :

 250V rms

0.1%

Frequency - 0.7V AC rms
Voltage - 0.1V AC rms

Summary of Contents for KM 2720

Page 1: ...Accuracy Overload Protection 250V rms Range Resolution 1 kW 4 MW 40 MW 10 kW 1 0 rdg 2dgts 1 0 rdg 2dgts 1 0 rdg 2dgts 1 0 rdg 2dgts 1 5 rdg 2dgts Range DIODE TEST Description Display read approx For...

Page 2: ...Transistorised Electronic Analog Digital Insulation Resistance Testers Digital Sound Level Meter Sound Level Calibrator Digital contact Non contact Type Tachometer Digital Non contact infrared Thermo...

Page 3: ...lectrical com THIS WARRANTY IS BUYER S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNE...

Page 4: ...eading can be read with the best possible accuracy When measuring voltage connect the test leads before your apply power to your circuit To be safe start by setting your meter to its highest range fir...

Page 5: ...tance Measurement Auto Power Off Maintenance 9 Battery Replacement 10 Fuse Replacement 10 Test Certificate 11 Warranty 13 11 MUMBAI TEST CERTIFICATE AUTORANGING CLAMPMETER This Test Certificate guaran...

Page 6: ...ith high voltage above DC 1000V orAC 750V 1 3 Be cautions when working at DC60V or AC30V such voltage may cause a shock hazard 1 4 When making measurements keep your finger behind the guard s plant on...

Page 7: ...a precis product Please do not promiscuously change the circuit or regulation resistance And pay attention to following 1 Do not use the Resistance Diode Transistor or Current range to test Voltage 2...

Page 8: ...01A 0 1A 0 01A 0 001A 40A 4A 2 0 rdg 2d 2 0 rdg 2d 0 01A 0 001A 400 mV 4 V 40 V 400 V Range AC VOLTAGE Model KM 2720 KM 2725 AC Accuracy 1 8 rdg 5d 750 V 1 0 rdg 3d 1 5 rdg 3d Note Input Resistance 1...

Page 9: ...tivity Frequency 0 7V AC RMS Voltage 0 1V AC RMS 0 2 rdg 3 DUTY Range 0 1 to 99 9 Unspecified Note Overload Protection 250V RMS Range RESISTANCE Accuracy 1 0 rdg 2d Note Overload Protection 250V RMS 4...

Page 10: ...circuit or component when the test leads are plugged into the current terminals 5 MEASUREMENT 5 1DC AC Current Measurement WARNING 1 Set the rotary switch to AC or DC 40A 200A position Then press REL...

Reviews: