background image

®

INDEX

Safety Rules................................................. 03

04

General Description.....................................

05

Low Voltage Testing.....................................

Page

Front Panel Layout....................................... 06

Preparation for Use...................................... 07

Checking and Proofing the Unit

07

...................

Typical Uses

08

..................................................

Broken Wires in Cables

08

...............................

High Voltage Testing

09

.....................................

09

Limitations of the 275HP Hi-Prox ................

Laboratory and Field Test Result

10

.................

Changing Batteries

10

......................................

11

12

Specifications

Limited Warranty

...............................................

...........................................

Caution, risk of electric shock.

Caution, refer to the user manual.

02

®

Specifications

Electrical

Detecting Ranges

Selection

Detects voltage from

240V

2kV
6kV

11kV

22kV
33kV

132kV
275kV

Variable from 80V
or depending on type of source

250V
500V

1000V
1500V
4000V
8000V

22kV

Mechanical

Bump Test :
Vibration Test :
Drop Test :
Impact Test :
Case Height :
Case Width :
Weight :

IEC68-2-29
IEC1010, clause 8.3
IEC1010, clause 8.4
IEC1010, clause 8.2
229 mm
96 mm
0.59 kg ( Batteries included )

Environmental

Operating Temperature :
Storage Temperature :
Humidity :
Cold Temperature :
Dry Heat :
Damp Heat :

-15°C to + 55°C
-20°C to + 65°C
93% RH @ 40°C
IEC68-2-1
IEC68-2-2
IEC68-2-3

11

Summary of Contents for 500HP

Page 1: ...high voltage KV However the 275 HP 500HP is a non contact tester and it is advised that the tester should never come in to contact with cables KV as this tester is merely a non contact AC proximity t...

Page 2: ...c 2800Vac 5500Vac 8200Vac 15500Vac 5cm 5cm 5cm 5cm 5cm 5cm From a distance of 5cm form the conductor the 275HP can detect 90Vac while on the 240Vac setting From a distance of 5cm it will start to dete...

Page 3: ...m 105cm On the 6kV position the 275HP detect 22000Vac from a distance of 75cm On the previous test while on the 2kV position the 275HP needed only 60cm to detect 22000V So if you suspect the conductor...

Page 4: ...URED 22kVac 22kVac 22kVac 22kVac 22kVac 22kVac o 90 o 90 o 90 o 90 o 90 o 90 3000Vac 4000Vac 6000Vac 11000Vac 22000Vac 33000Vac 1cm 9cm 14cm 25cm 36cm 8 The rotary setting selector is now positioned o...

Page 5: ...en misused altered neglected contaminated or damaged by accident or abnormal conditions of operation or handling KUSAM MECO authorized dealer shall extend this warranty on new and unused products to e...

Page 6: ...er to the user manual 02 Specifications Electrical Detecting Ranges Selection Detects voltage from 240V 2kV 6kV 11kV 22kV 33kV 132kV 275kV Variable from 80V or depending on type of source 250V 500V 10...

Page 7: ...stick Verify the rotary switch setting before measuring Make sure it is on the correct setting for your application Always check that the 275HP Hi Prox is working before and after the test Do not touc...

Page 8: ...ed and indicates the wrong information to the user 09 General Description The 275HP Hi Prox consists of an internal pickup sensor plate a rotary switch as sensitivity selector a sound annunciator high...

Page 9: ...a bunched neutral and earth cable as seen in a flexible cable the distance is reduced to 5 cm 05 Typical Uses Identify and check live cables Check and detect live high voltage cables using extension h...

Page 10: ...nst a low voltage live conductor or rub the dome with a cloth or against an item of clothing as this generates a static DC which triggers the detection of circuit The light and beeper should go on as...