B-series Operation 

B - 9 

Auto Exit 

The flow meter has a built in 

Auto Exit

 timer that will return the meter to 

Run Mode

 from 

any of the user modes if there has been no user input for more than 3 minutes.  If the 
user placed the meter in 

Program Mode

 and made changes and didn’t return the meter 

to 

Run Mode

, the meter will save the changes to EEPROM before returning to 

Run Mode 

after 3 minutes of no user activity. 

Entering Data 

Data is entered using the numeric (

0-9

), minus (

-

) and decimal (

.

) keys for floating point 

or integer parameters.  After the value is entered, the 

E

 key is pressed to accept the 

entry.  When entering data, the 

D

 key will clear one character to the left, similar to the 

backspace key on a computer keyboard.  The 

C

 key will clear the entire value and restart 

the entry of the value at the first digit.   
 
For parameters with a selection list, the up arrow (

^

)

 

and down arrow

 

(

v

) keys are used 

to scroll the list to the desired value.  When the desired list value is displayed, the 

E

 key 

is pressed to accept the entry. 
 
String/text parameters are entered using the numeric keys similar to entering a text 
message on a cellular phone.  Alphabetic characters and special characters (eg <,>,%, 
etc) are mapped to the numeric keys as follows: 
 

Keypad Key  Character Map 

0, <sp>, (, ), +, ,, <, > 

1, /, #, :, $, @, %, & 

2, A, B, C 

3, D, E, F 

4, G, H, I 

5, J, K, L 

6, M, N, O 

7, Q, R, S 

8, T, U, V 

9, W, X, Y, Z 

 
The alphabetic and special characters are entered by repeated pressing of the 
corresponding numeric key.  When the desired character is displayed, the 

E

 key is 

pressed to accept the character and advance the cursor to the right.  During text input 
mode, a cursor is visible to indicate the current character entry position on the display.  
As with numeric entry, the 

D

 key will clear one character to the left and the 

C

 key will 

clear the entire string and restart text input at the first character of the string. 
 

Summary of Contents for MFT-B Series

Page 1: ...the Flow The Run Mode display can be configured to display other meter variables see section below If the cover is removed as shown in the picture the optional keypad is accessible to view change the...

Page 2: ...seconds for the whole boot process under flow For a full description of this and flow rate dependent boot times see this section The parameters to configure or setup the mass flow transmitter are acc...

Page 3: ...and data entry is blocked Display Mode is invoked by pressing D when the flow meter is in Run Mode Log Mode is the mode used to request log reports that are sent to the flow meter USB port No access c...

Page 4: ...nding on the user mode invoked the user will be prompted to enter an access code ENTER ACCESS CODE An access code is entered using the numeric keys on the keypad and pressing E to accept the entry The...

Page 5: ...ar with the Option s associated with the menu options the Quick Jump navigation allows the user the enter the option using the numeric keys and press E to quickly invoke the menu option The following...

Page 6: ...PID SETUP 22 Manual PID Adjust 22 PID CONTRL 23 Setup Drift Check 23 DRIFT CHCK 24 Change User Password 24 CHNG PWORD 25 Update FROM EEPROM 25 GET EEPROM 26 Set Bootup Output Delay 26 BOOTUP DLY The...

Page 7: ...rection Data 15 VRMS DATA 16 Remote Correction Factor Data 16 REMOTE CF 17 Select Gas Calibration Curve 17 CAL CURVE 18 Setup Data Logging 18 DATA LOG 19 Setup Modbus Communication 19 MODBUS COM 20 Se...

Page 8: ...and not changed LOG MODE MENU OPTIONS Option Menu 1 Event Log 1 EVENT 2 Min Max Data 2 MIN MAX 3 Trend Log 3 TREND 4 System Configuration 4 CONFIG 5 System Monitored Data 5 RUN DATA EXTENDED UTILITIE...

Page 9: ...st digit For parameters with a selection list the up arrow and down arrow v keys are used to scroll the list to the desired value When the desired list value is displayed the E key is pressed to accep...

Page 10: ...ho is off Note The meter Tag Name and other text parameters can be entered as a continuous string using a remote terminal keyboard versus single characters followed by the ENTER key by holding the SHI...

Page 11: ...8E 07 FLOW VEL FLOW 0 0000 SCFM VEL 0 00000 SFPM TAG FLOW TAG NAT GAS FLOW 0 0000 SCFM FLOW TEMP FLOW 0 0000 SCFM TEMP 82 003 DEGF If SCROLLED format is selected for the Run Mode Display the meter wil...

Page 12: ...value with units will be on line 2 Flow FLOW RATE 0 0000 SCFM Temp TEMPERATURE 82 52 DEGF Velocity VELOCITY 0 0000 SFPM Totalized Flow TOTAL FLOW 183545 0 SCF Tag Name TAG NAME NAT GAS24 For scrolled...

Page 13: ...changes in Program Mode the changes are automatically saved to EEPROM memory when the user exits from Program Mode Configuration Upload Download using Xmodem The upload download process allows the use...

Page 14: ...erminal echo ON and OFF Calibration of the Analog Output A menu is available to perform the calibration of the analog output s on MFT series flow meters You enter the Analog Output Calibration menu an...

Page 15: ...can be setup to energize a relay output when an alarm event occurs The solid state relays SSR are SPST and open circuit when the meter is unpowered The second alarm mechanism is the NE 43 Alarm Meter...

Reviews: