Pulse length:

 Select the desired pulse length with the 

left / right 

arrow keys. 

If the TDR range is adjusted, the transmission time of the pulse changes. The 

pulse length must be increased so that the device can overcome signal atte-

nuation and continue to record the length of the cable. The larger the range 

selected on the TDR, the wider the transmitted pulse.

Z:

 The impedance is a characteristic of the cable to be tested. The desired 

impedance is selected with the 

left / right

 arrow keys (the cable impedance is 

determined automatically in the AUTO test).

TDR Menu

Short pressing of the 

SEL

 key al-

lows scrolling through the different 

functions of the 

up / down

 control 

keys.

1. Length:

 Selection of length ranges from 0 to approx. 14,000 metres

2. Y Zoom:

 Enlarges the view of the measuring range in 6 dB increments

3. X Zoom:

 Enlarges the view of the measurement window

4. Cursor:

 Fade in the cursor. To move quickly, hold down the 

left / right

 con-

trol keys. The 

up

 key is used to display the second cursor; the inactive cursor 

changes its colour to black.
Further cursor modes:

1x  :

 C1 Absolute position of cursor 1, cursor 1 is active

2x  :

 C2 Absolute position of cursor 2, cursor 2 is active

3x  :

 

ΔC1 Difference between cursor 1 and 2, cursor 1 is active

4x  :

 

ΔC2 Difference between cursor 1 und 2, cursor 2 is active

This function can be used to measure two reflection points, e.g. the distance 

between two distributors, joints or distr defect.

C1:40.2m

0.67

Cursor

0m

150   ~

300m

Summary of Contents for 0.49210

Page 1: ...es including excerpts require prior written approval of Kurth Electronic GmbH All of the brand names and trademarks cited herein are the property of their registered owners Operating Manual Kurth Elec...

Page 2: ...nally supported by a second cursor The freeze function allows you to examine the curve accurately a feature available on the very few TDRs in this price range The high screen resolu tion with backligh...

Page 3: ...s must be proper clean and without damaged or cracked insulation The meter is protected from splash water and dust by the front foil but it is not waterproof It only needs to be opened to change the b...

Page 4: ...ap 4mm banana sockets Fall protection Battery indicator LCD display ESC key AUTO test or main menu SEL button Display menu or TDR menu Control keys UP DOWN LEFT RIGHT ON OFF key Battery compartment Be...

Page 5: ...trap Display of cursor absolute position Start of the display area Function of the Up Down keys Display VF Battery indicator End of display area Display input AC or DC Display Impedance Cursor long pr...

Page 6: ...selection fields XXX which are operated with the left right control keys Once the selection has been made the process must be completed with the ESC key TDR measurement Cable parameter Cable Data tra...

Page 7: ...ing the update process Time setting the time in 24 hour format Date Setting the date in the format DD MM YY Exiting the Settings menu with ESC TDR Menu Press and hold the SEL key to open the TDR menu...

Page 8: ...ling through the different functions of the up down control keys 1 Length Selection of length ranges from 0 to approx 14 000 metres 2 Y Zoom Enlarges the view of the measuring range in 6 dB increments...

Page 9: ...If the shor tening factor for the cable to be tested was not correctly specified the dis played distance is incorrect Examples With the TDR method the device sends a pulse to the cable which is re fle...

Page 10: ...faults where the actual end of the cable is not visible For a measurement from both ends the combined result should cor respond to the expected cable length Even if the actual cable end is shown on th...

Page 11: ...KE2100 to the KE2100 Manager The KE2100 is connected to your PC via Bluetooth To activate the Blue tooth module of the KE2100 select Data transfer in the main menu of the device The message Bluetooth...

Page 12: ...ed by the instrument Downloaded measurements stored on the PC can also be evaluated at a later time without requiring a connection to the instrument To view and manage the cable databases stored in th...

Page 13: ...Replace the edge protector on the housing d Tighten the screws e Do not mix old and new batteries Alkaline and NiMH batteries are portable batteries and must be disposed of in accordance with applica...

Page 14: ...tput impusle max 20 V pp Pulse lengths 12 25 50 100 200 500 1 000 2 500 ns Velocity factor variable from 0 2 to 0 99 in 0 01steps Impedance 75 100 120 150 Signal type symmetrical Zoom factor in 6 dB s...

Page 15: ...g with crocodile clip Power supply 4x LR6 AA batteries NiMH Operating time depending on type and quality of battery up to approx 30 hours Scope of delivery Size Dimensions 195 x 100 87 x 45 mm Weight...

Page 16: ...li cations for which it was not intended can lead to incorrect measurements and may damage the device The relevant safety regulations in VDE 0100 0800 and 0805 must be adhered to The usage of connecti...