Usage
Press the
ON / OFF
key to turn the TDR on or off.
The TDR trace is displayed immediately after the
ON / OFF
key is pressed.
Briefly press
ESC
to activate the AUTO test:
The impedance of the cable to be tested, pulse width and gain are auto-
matically selected for the selected range. (The cable must be longer than 10
meters or 30 feet).
Main menu
Long press of the
ESC
key:
Basic Operating Instructions
The menu structure in the KE2100 consists on the one hand of a menu
bar structure, which is confirmed and exited with the
SEL
key. On the
other hand there are selection fields
<XXX>
, which are operated with the
left / right
control keys. Once the selection has been made, the process
must be completed with the ESC key.
TDR measurement
Cable parameter
Cable
Data transmission
Settings
Measurement /
Exit menu
VFL value
Cable database
Activate Bluetooth
Language
Unit
Battery type
Backlight
Auto-Off
Contrast
Velocity factor
Program update
Time
Date
German / English
-20 – 50 (Def. 20)
m, ft
VF or V/2
Battery, rech. batt.
Start the update
process
Duration: 0 – .. Sek.
Settings time
Duration: 0 – .. Min.
Settings date
TDR measurement:
Measurement mode with display of the TDR trace and
exit of the main menu
Cable parameters:
Change the VFL value with the
Up / Down
keys. The
Velocity Factor depends on the cable being tested and must be set correctly
to display the measured distance correctly.