7
OPERATING INSTRUCTIONS
HYDRAULIC
OPERATING INSTRUCTIONS
For Basic Hydraulic Set-Up:
1. Remove plastic caps from pressure and release ports on Hydraulic pump.
Install 90° fittings.
2. Remove plastic caps from pressure and release ports on hand or foot
valve. Install straight fitting.
3. Install straight fitting on the Hydraulic Unit (1/8 NPTF) of the 3800H vise.
4. A filter-lubricator-regulator combination is recommended to insure
clean air coming into the unit. See Clamping Force Chart for air pressure
required to attain desired clamping force (pg. 4 & 8).
5. Connect the FRL to the input air port on the KHP3 hydraulic pump.
6. Connect the hydraulic line to the hydraulic unit on the vise and then to
the output side of the hydraulic pump
7. If using a hand valve connect the 3-line cluster
8. Apply air pressure (80 PSI maximum) to system. Loosen swivel fitting at
vise and bleed air. Tighten fitting. Release air pressure.
9. Repeat previous step until all air is purged
10. System is now ready for use.
NOTE: For multiple vise hook-ups, call factory for recommendations.