background image

- TIMER: The hood is equipped with a device for automatic stop after 5 (or 10) minutes. To activate this function, see
point 4 of the instructions.
- CLOCK: the time can be shown on the display. To activate this function or set the time, see point 5 of the instructions.
- SENSOR SENSITIVITY: You can adjust the sensitivity of the sensor according to your specific needs. To access
this function, see point 6 of the instructions.
- INSIDE TEMPERATURE INDICATION: The inside temperature of the room can be shown on the display. To activate
this function, see point 7 of the instructions.
- OUTSIDE TEMPERATURE INDICATION (optional): It is possible to have the outside temperature shown on the display.
To activate this function, see point 8 of the instructions.
- GREASE FILTER CLEANING INDICATION: The hood signals when it is time to clean the grease filters. See point 9
of the instructions.
- CHARCOAL FILTER REPLACEMENT INDICATION: The hood signals when it is time to replace the charcoal filters (for
appliances in the filtering version). See point 10 of the instructions.

1. Key “A” (ASC function) : To activate the sensor function, press key “A”.  With the sensor activated, the hood switches
on automatically in the presence of any type of odour, steam, smoke, or heat from the cooking process, and also in the

presence of any anomalous gas leaks in the environment. When the sensor is active, the display shows the symbol 

.

To disactivate the sensor, press the key A. With the sensor activated, pressing the - key or the + key takes you directly

to the manual function and the symbol 

 is shown.

2. Key 

 : Light On/Off.

3. Minute counter: To activate the counter, press the “MENU” key (the symbol 

 appears on the display), then press

“ok”. The display shows the number 00.00 blinking. Using the - and + keys you can set the desired number of minutes
(from 1 to 99); keeping the - or + key pressed, the number of minutes scrolls rapidly. Press “ok” to confirm, then press
“MENU” to exit. When the minutes have elapsed, an ACOUSTIC SIGNAL is emitted and the indication blinks on the display:
press “ok” to disactivate it (otherwise, it is disactivated automatically after 5 minutes).
To disactivate the counter at any moment, press the “MENU” and “ok” (reset) keys together.
4. Timer: When the timer is activated, the hood stops automatically after 5 minutes (or 10). To activate the timer, press

the “MENU” key and then the - and + keys until the blinking symbol 

 appears on the display; confirm by pressing “ok”.

You can select the timer for 5 or 10 minutes by pressing the - and + keys, and then press “ok” to confirm. To exit from
the menu, press the “MENU” key.
5. Clock: To activate the clock function and set the time, press the “MENU” key and then the - and + keys until the 4
digits appear on the display blinking; set the time using the - and + keys, then confirm with “ok”. To exit from the menu,
press the “MENU” key. To disactivate the clock function, press the “MENU” and “ok” (reset) keys together.
6. Sensor sensitivity: To adjust the sensitivity of the sensor, press the “MENU” key and then the - and + keys until the
symbol 

 blinks on the display. Then press “ok”, select the sensitivity from 1 to 9 using the - and + keys and confirm

with “ok”. To exit from the menu, press the “MENU” key”.
7. Inside temperature indication: To view the inside temperature on the display, press the “MENU” key and then the - key
(or + key) until the display shows “In 18°C” or similar; then press “ok”. The inside temperature is measured by a measuring
device (included) which can be positioned anywhere in the room.
8. Outside temperature indication (optional): To view the outside temperature on the display, press the “MENU” key and
then the - key (or + key) until the display shows “Out 15°C” or similar; then press “ok”. The outside temperature is measured
by a measuring device (optional) that can be positioned outside the building, protected from water (maximum distance
on a direct line: about 15 m).

9. Grease filter alarm: After approximately 30 hours of operation, the display will show the symbol 

, indicating that it

is time to clean the grease filters. Once the filters have been cleaned, restart the hour count by pressing the “MENU”
and “ok” (reset) keys at the same time.

10. Charcoal filter alarm: After approximately 120 hours of operation, the display will show the symbol 

, indicating that

it is time to replace the charcoal filters.  Once the filters have been replaced,  restart the hour count by pressing the “MENU”
and “ok” (reset) keys at the same time.

LIST OF SYMBOLS

SPEED (4 speeds  + extra-high speed)

AUTOMATIC SENSOR

19.38

CLOCK

MINUTE COUNTER

Summary of Contents for KD9875.1

Page 1: ...use and installation instructions Instructions d utilisation et avis de montage Gebruiksaanwijzing en montagehandleiding Istruzioni di uso e di montaggio Instrucciones de uso y de montaje Instruções de uso e de montagem ÏÄÇÃÉÅÓ ÃÉÁ ÔÇÍ ÅÃÊÁÔÁÓÔÁÓÇ ÊÁÉ ÔÇ ÑÇÓÇ F NL I E P GR ...

Page 2: ...liance if the symbol is NOT printed read the following ATTENTION Thisappliancemustbeearthed Whenmakingtheelectricalconnections checkthatthecurrentsockethasaground connection The following warning is valid in the United Kingdom only in case your cable is not furnished with a plug read the following instructions as the colours of the wires in the mains lead of this appliance may not correspond with ...

Page 3: ...as been completed without removing the hood mark the other 2 holes to be drilled C in the wall Remove the hood and drill the holes marked 8 mm diameter Then use the 2 screw anchors and the 2 screws provided for final fixing 7 Fixing of the telescopic decorative flue Adjust the width of the support bracket D of the telescopic flue by means of the screws E as shown in Fig 9 then by means of the scre...

Page 4: ... moment press the MENU and ok reset keys together 4 Timer When the timer is activated the hood stops automatically after 5 minutes or 10 To activate the timer press the MENU key and then the and keys until the blinking symbol appears on the display confirm by pressing ok You can select the timer for 5 or 10 minutes by pressing the and keys and then press ok to confirm To exit from the menu press t...

Page 5: ...ot touch the new lamp with bare hands Insidetemperaturemeasuringdevice Thehoodissuppliedwithadeviceformeasuringtheinsidetemperaturethat can be positioned anywhere in the room The temperature measured is shown on the hood control panel display If this function is not active use the controls on the hood as follows press the MENU key then press the or key until the display shows In 18 C or similar th...

Page 6: ...reil n a pas de câble flexible qui ne peut pas être séparé ni de prise ou bien d autre dispositif qui garantisse le débranchement de tous les pôles du réseau avec une distance d ouverture entre les contacts d au moins 3 mm ces dispositifs de séparation du réseau doivent alors être prévus dans l installation fixe Si votre appareil est muni d un câble d alimentation positionner l appareil de manière...

Page 7: ...ue Réglerlalargeurdel étrierdesupport D dutuyautélescopique à l aide des vis E indiquées sur la Fig 9 ensuite à l aide des chevilles et des vis F fournies fixer le support au plafond en faisant attention qu il soit dans l axe de la hotte Seulement pour la version évacuation Raccordez le conduit pour l évacuation de l air à la bouche de sortie d air de la hotte utilisez un tuyau souple et bloquez l...

Page 8: ...1 2 3 4 5 ...

Page 9: ...6 7 8 9 10 ...

Page 10: ...11 12 13 14 15 ...

Page 11: ...16 17 18 ...

Page 12: ...stfach100132 D 45801Gelsenkirchen Küppersbuschstr 16 D 45883Gelsenkirchen Telefon 0209 401 0 Telefax 0209 401 303 www kueppersbusch de KüppersbuschGes m b H Eitnergasse13 1231Wien Telefon 01 86680 0 Telefax 01 8668072 04307549 3N ...

Reviews: