background image

in the fixed installation. If your unit features a power lead and plug, position this so the plug is accessible.
Always switch off the electricity supply before carrying out any cleaning or servicing operations on the appliance.

USE

Avoid using materials which could cause spurts of flame (flambées) near the appliance.
When frying, take particular care to prevent oil and grease from catching fire. Already used oil is especially dangerous
in this respect. Do not use uncovered electric grates.
To avoid possible risks of fire always comply with the indicated instructions when cleaning anti-grease filters and
when removing grease deposits from the appliance.

MAINTENANCE

Thorough servicing guarantees correct and long-lasting operation.
Any fat deposits should be removed from the appliance periodically depending on amount of use (at least every 2
months). Avoid using abrasive or corrosive products. To clean painted appliances on the outside, use a cloth dipped
in lukewarm water and neutral detergent. To clean steel, copper or brass appliances on the outside, it is always best
to use specific products, following the instructions on the products themselves. To clean the inside of the appliance,
use a cloth (or brush) dipped in denatured ethyl alcohol.

DESCRIPTION

The hood may be in the filtering or the ducting version.

Filtering version

 (Fig. 1): The hood aspirates the kitchen air saturated with fumes and odours, purifies it through

the grease filters and charcoal filters and returns clean air into the room. For constant efficiency, the charcoal filters must
be replaced periodically. The charcoal filters are not supplied.

Ducting version 

(Fig. 2): The hood aspirates the kitchen air saturated with fumes and odours, passes it through the

grease filters and expels it to the outside through an outlet pipe. With this version the charcoal filters are not required.
Decide from the outset on the type of installation (filtering or ducting). For greater efficiency, we recommend you install
the hood in the ducting version (if possible).

INSTALLATION

ATTENTION: Two persons are required for proper installation; the unit should be installed by a qualified operator.

Remove the grease filters before proceeding with the assembly instructions. This will make the appliance easier to handle.

1.

Removal of grease filters

:  Pull the lock and move up the metallic grille.(Fig.3a) take away the grease filter pushing

down and rotating outside (Fig. 3b).

INSTALLATION IN DUCTING VERSION

:

 Before fixing, the outlet pipe for air evacuation to the outside must be installed.

Use an outlet pipe with: – minimum indispensable length; – minimum possible bends (maximum angle of bend: 90°); – certified
material (according to the State); – an as smooth as possible inside. It is also advisable to avoid any drastic changes
in pipe cross-section (recommended diameter: 150 mm). For air evacuation to the outside, follow all the other instructions
given on the “Warnings” sheet. Prepare the power supply within the telescopic chimney (for the electrical connection, follow
all the other instructions on the “Warnings” sheet).

2.

Mount the plate of the electrical system

 fixing it with 2 screws and 2 metal washers (Fig. 3C).

3.

Fixing to the wall: 

Draw a line on the wall in vertical line with your hob. Mark the first 2 holes to be drilled in the

wall, respecting the distances indicated in Fig. 4. Drill the 2 holes and fit the screw anchors provided. Bear in mind that
the distance between the lower edge of the hood and the hob must be 350 mm. Fix the metal bracket (A) to the wall using
the 2 holes just drilled (Fig. 5); the screws for fixing the bracket are provided. Use the 2 cut-out triangles on the bracket
to position it exactly along the vertical axis of the hood. Hang the hood on the bracket (Fig. 6). Adjust the horizontal position
moving the hood to the right or left so that it is aligned with the wall units. If you also need to adjust the hood in height,
operate on the adjusting screws (B) provided. When adjustment has been completed, without removing the hood, mark
the other 6 holes to be drilled (C) in the wall. Remove the hood and drill the holes marked (8 mm diameter). Then use the
6 screw anchors and the 6 screws provided for final fixing.

4.

Install  the flange 

in the device air outlet  and press slightly (Fig.7)

5.

Fixing the telescopic flues:

5a - Assemble the tube support using  a 4 screws kit  (Fig.8);   then, by means of the screw anchors and screws (F) provided,
fix the bracket to the ceiling in such a way that it is positioned along the axis with your hood (Fig.9).
5b - Connect the air outlet pipe to the air vent of the hood. - Use a flexible pipe and lock it to the air vent of the hood
with a metal hose clamp - Fig.10 (pipe and clamp are not provided). - For exhaust hoods, turn the upper flue over so that
the air exhaust grid is in the lower section (Fig.11).
5c - Plug in the hood. Insert the extension flues setting them on the hood; extend the upper flue to the ceiling and secure
with the 2 screws (H) - Fig.12.

INSTALLATION IN FILTERING VERSION

Prepare the power supply within the telescopic flues (for the electrical

connection, follow all the other instructions on the “Warnings” sheet).

Fixing to the wall: 

for fixing to the wall refer to the instructions for the ducting version (see points 2, 3, 4), then continue

Summary of Contents for KD9575.0

Page 1: ...n GB Instructions for use and installation instructions Instructions d utilisation et avis de montage Gebruiksaanwijzing en montagehandleiding Istruzioni di uso e di montaggio Instrucciones de uso y de montaje Instruções de uso e de montagem F NL I E P ...

Page 2: ... disposal duct In addition exhaust air should not be discharged into a wall cavity unless the cavity is designed for that purpose Theroommustbewellaeratedincaseahoodandsomeotherheatequipmentfedwithanenergyotherthanelectricity gas oil coal heaters etc operate at the same time In fact the intake hood disposing of air could create a vacuum in the room The vacuum should not exceed 0 04mbar This preven...

Page 3: ...eoutsidemustbeinstalled Useanoutletpipewith minimumindispensablelength minimumpossiblebends maximumangleofbend 90 certified material according to the State an as smooth as possible inside It is also advisable to avoid any drastic changes in pipe cross section recommended diameter 150 mm For air evacuation to the outside follow all the other instructions givenonthe Warnings sheet Preparethepowersup...

Page 4: ...the keys D and E The set sensitivity is indicated by the 4 green LEDs By means of buttons C and D the desired sensitivity is set Fig 16 S Store the new sensitivity by pressing the key E ATTENTION TOPREVENTDAMAGINGTHESENSOR DONOTUSESILICONEPRODUCTSNEARTHEHOOD Grease filters special attention must be given to the grease filters which must be periodically cleaned whenever the grease filter alarm trip...

Page 5: ...3a 4 1 2 3b 3C ...

Page 6: ...8 6 9 7 10 5 ...

Page 7: ...12 14 13 15 11 ...

Page 8: ...19 18 16 17 ...

Reviews: