Electrical connection
■
The electrical connection must be carried out by a qualified
electrician who is authorised to carry out such work!
■
Statutory regulations and the connection specifications issued by the local
power supply company must be strictly observed.
■
When connecting the appliance it must be ensured that there is a device
which makes it possible to disconnect it from the mains at all poles with a
contact opening width of at least 3 mm. Line-protecting switches, fuses or
contactors are suitable cut-out devices.
■
When connecting and repairing the appliance disconnect it from the
electricity supply with one of these devices.
■
It must not be possible to touch components which are insulated under
operating conditions.
■
The earth wire must be so long that if the strain relief fails, the live wires
of the connecting cable are subjected to tension before the earth wire.
■
Any superfluous cable must be removed from the installation area beneath
the appliance.
■
The induction cooking hob is provided at the works with a temperature-
resistant cable with connector box for cooker connection cables.
■
The connector box is fastened on the kitchen wall behind the fitted
cupboard. If no built-in oven is installed underneath, the connector box can
also be fastened to the furniture under the hob.
■
When installing the connector box, a minimum distance to the ground of
300 mm is to be observed in accordance with the drawing.
■
The connector box must not come into contact with hot parts of the
appliance.
■
The connector box must not be used as a power distributor for other
appliances.
■
The mains connection is made in accordance with the connection diagram
on the connector box. The connection may only be made in the connector
box.
■
The connector box must not be removed.
■
The attached connection line must be replaced by the Küppersbusch
Customer service in the event of damage.
■
The end of the green/yellow protective conductor must be stripped more
than the other conductors.
Attention:
Incorrect connection results in the total destruction of the power electronics.
[
When installing the connector box, a minimum distance to the ground of
300 mm is to be observed in accordance with the drawing.
Electrical connection
Permanent connection above a cooker socket.
Connection diagram
is depicted on the underside of the appliance,
suitable for the various types of mains.
Electrical connection
Permanent connection 400 V 2 N
~
50 Hz
Electronics
Voltage: 230 V
Electrical connection 6,8 kW
400 V 2 N
~
safety current 16 A
230 V 1 N
~
safety current 32 A
230 V 3
~
safety current 16 A
Connection cable
Use H 05 RR-F or H 07 RN-F.
Cable length as necessary.
Base
Single-phase connection 230 V phase against neutral conductor
Two-phase connection 400 V system with 230 V
phase against neutral conductor
Three phase curent 230 V phase against phase
Cable to
hob
Feeding of
cooker socket
The colour of the cable conductors can differ.
The connection diagramm and the terminal numbers are the decisive factors.