Installation

Note

The KÜPPERSBUSCH induction hob may only be built-in in accordance 
to the instructions included in this manual!

In case of a failure to observe these instructions, KÜPPERSBUSCH shall 
decline any liability and the approved marks of conformity become 
invalid!

General

F

Due to the installation dept of 200 mm the induction hob cannot be 
installed above an standard application!

■ 

Lift off the glass ceramic surface only laterally, never at the front panel!

■ 

Do not use a screw driver to lever the appliance out of the opening - This 
will damage the frame of appliance. When removing the appliance press it 
from the bottom out of the opening.

Installation conditions

■ 

The plastic finish or the veneer of built-in kitchen furniture must have been 
produced using a heat-resistant adhesive (100 °C).

■ 

The working surface must be installed absolutely horizontally and the opening 
must be cleanly cut.

■ 

Ventilation openings are to be provided in the back of the cupboard.
The heated air escapes through the ventilation openings in the rear.  An air 
channel to be installed (see following descriptions) prevents the  heated 
airflowing back to the cold air intake side.

■ 

No cross-bars may be in the area of the cut-out underneath. They have to 
be reduced at least to the opening size.

■ 

Each time the appliance is removed from the worktop, replace the seals.

Electrical connection

■ 

Statutory regulations and the connection specifications issued by the local 
power supply company must be strictly observed.

■ 

Ensure that all live connections are safely insulated when installing the oven. 

■ 

The appliance is supplied ready to plug in. It should be connected only to 
a properly protected wall socket.  Installing and wiring a socket or replacing 
the connection cable should only be performed by an electrician and in 
observance of the relevant regulations. 

■ 

If the socket is inaccessible after the installation, safety regulations require 
that an all-polo isolator with a contact opening of at least 3 mm be used 
on the installation side.

■ 

The wall-socket can be mounted under the working top below the hob or 
in a side cupboard in the wall. Do not mount it above the cooking area!

Connection

standard mains plug into a wall socket.

Power consumption 

at 230 V: 3.5 kW, 
at 235 V: 3.6 kW

Power supply

230 - 240 V, 50 Hz

Safety current

protected separately with 16 A!

Dimensions and distances

■ 

This appliance can be mounted with two sides to a wall or a cupboard side 
with a distance of at least 40 mm. The third side side may only be placed 
next to a appliance of the same height at the most.

■ 

Installation above a cover plate:

A ventilation slit of at least 7 mm must be provided above the panel. Cold 
air is drawn in through this front ventilation slit. If no cover plate is installed 
underneath normally the ambient air is sufficient as air coolant. A ventilation 
slit is not necessary.

F

The distance to mounted cupboards should be for technical reasons at 
least 300 mm.

■ 

Cooker hoods or wall 
cupboards mounted above 
the hob must be installed 
with a minimum distance of 
650 mm to the hob.

Installation dimensions

■ 

When installing several 
hobs side by side please 
observe the minimum 
distances between the 
worktop openings as 
shown in the drawings:

Aspiration

Top view

Detail

Hob

Worktop

Summary of Contents for EWI 457.0

Page 1: ...tions for use and installation instructions Instructions d utilisation et avis de montage Gebruiksaanwijzing en montagehandleiding Istruzioni di uso e di montaggio Instrucciones de uso y de montaje In...

Page 2: ...or a lengthy period the power electronics may no longer be cooled to the necessary extent at room temperature To ensure that no excessive temperatures occur in the electronics the power of the cooking...

Page 3: ...on Put the lid on the pan and switch off the cooking zone The glass ceramic hob is extremely robust Avoid dropping hard objects onto the glass ceramic hob Pointed objects falling onto your hob might b...

Page 4: ...r you The pot recognition The induction cooking zone checks in brief intervals if a wok has been placed on the cooking zone If no wok has been placed on the operating cooking surface will appear in th...

Page 5: ...the sensor lock Safety functions If two or more sensor keys are pressed at the same time e g when a pan is mistakenly put onto a sensor key no function is activated After 10 seconds the appliance swi...

Page 6: ...ith the edge of the scraper and take care not to damage the sealing with the edge Do not use the cleaning scraper in the bulge as otherwise it will scratch the surface What to do if trouble occurs Rep...

Page 7: ...tions are safely insulated when installing the oven The appliance is supplied ready to plug in It should be connected only to a properly protected wall socket Installing and wiring a socket or replaci...

Page 8: ...he clips Align the clips carefully and drive them in with a hammer Worktops with more than 30 mm thickness With workingtops with 30 mm thickness the clips have to be screwed down with two screws not s...

Page 9: ...for 30 mm work surfaces for 40 mm work surfaces Insert the cooking area surface edge at the back and carefully lower it Use manual pressure on the clips here Press the cooking area surface down until...

Reviews: