background image

 

 
 
Install the Cooktop into the cabinet. Install the supplied hold down brackets (A) to the underside of the Cooktop using the 
supplied Phillips head screws (B) as shown in Fig. 6. Slide the hooks into position and secure the cooktop to the 
countertop. Trim any exposed gasket seal. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Gas Connection 

 

Check the ‘gas type’ sticker attached to the Cooktop. Details of the injector sizes used are recorded on the data plate 
located on the base of the Cooktop. 
 
Remove the regulator from the cartoon and install to the Cooktop. The inlet connection has a ½” B.S.P. male thread. It  
Is essential that the elbow on the appliance be held firmly with a spanner wrench when connecting the supply.  
DO NOT OVER TIGHTEN. The regulator is adjustable for both 

NAT

 gas (4” w.c.) and

 L.P 

gas (11” w.c.) 

 
After installing the gas supply and securing all connection make sure that all controls knobs are set to the “OFF” position. 
and turn on the gas supply to the unit. Using soap and water solution or an electronic gas leak detector, check each gas 
connection one at a time. If using a liquid solution, completely cover the entire connection and inspect for  
bubbles. If any leaks are discovered, shut off main supply, repair the leak and retest. Make sure that the work area is 
properly ventilated. When all connections have been tested and no leaks discovered.  
 
WARNING! Do not use an open flame, such as a match or cigarette lighter to check for leaks. Serious injury or death 
could result if a leaking connection is ignited.  
 
To check inlet gas pressure being supplied to the Cooktop proceed with the following: 
 
A)

 

Disconnect electric power before pressure checking is carried out 

B)

 

Take off one of the gas burner caps and the relative flame spreader in order to gain access to the burner orifice. 

C)

 

Attached the test meter to the outlet of the orifice. Turn the gas valve knob to the maximum position and keep the 
knob depressed. The meter should register 4” w.c. on NAT gas and 11” w.c. on LP gas. 

D)

 

Once the testing is complete, replace the burner cap and the flame spreader and reconnect electrical supply 
 

To test the operation of the Cooktop, turn on each burner and check for proper operation. Check each burner for a clear 
blue flame without yellow tipping. If the flame appears to be uneven or excess yellowing, check the positioning of the 
burner cap and flame spreader.  

 

Sometimes the burners will not ignite immediately and seem to “Blow” slightly when they ignite. This is normal on LAP 
gas due to the heaviness of the gas. Also, if any air is present in the gas system, a “Sputtering” condition can occur. Both of 
these conditions are normal and do not affect the performance of the Cooktop. 
 
If after following the instructions given and satisfactory performance cannot be obtained, contact your local gas authority 
for advice and assistance 
 

 

Fig. 6 

Summary of Contents for GMS 955.1

Page 1: ...Gas Cooktop Installation User and Service Instructions GMS 955 1...

Page 2: ...fied installer service agent or gas supplier Read this instruction booklet before installing and using the appliance The Manufacturer will not be responsible for any damage to property or to persons c...

Page 3: ...installed between the main gas supply line and the Cooktop The regulator must be set to the proper gas supply The gas pressure required on this unit is 4 Water column Natural and 11 Water column Liqui...

Page 4: ...ge of the appliance and the side wall and B3 is the minimum clearance between the back edge of the cooktop and the back cabinet wall Minimum Clearances Inches Millimeters B1 1 3 8 35 B2 3 90 B3 3 76 B...

Page 5: ...C 8 215 D 1 8 22 Installing the Cooktop Please inspect all packing materials before discarding After removing all packaged installation Parts from the box make sure that the Cooktop is not damaged an...

Page 6: ...aks discovered WARNING Do not use an open flame such as a match or cigarette lighter to check for leaks Serious injury or death could result if a leaking connection is ignited To check inlet gas press...

Page 7: ...ertified and licensed gas installer Failure to comply may result in improper operation which could result in injury or death Please consult your local governing officials for all Federal State and loc...

Page 8: ...rside edge of the burner cap Regulator adjustment for L P Gas The gas pressure regulator supplied is a universal type that can be set for either Nat or L P gas The unit is shipped set To NAT gas 1 Uns...

Page 9: ...cedures outlined in this paragraph Automatic electric ignition Turn the knob that corresponds to the burner selected counterclockwise to the MAXIMUM position at the etched star Large flame and press d...

Page 10: ...ing a suitable product which can be found in a supermarket which is specifically designed for stainless steel Never use abrasive powders The burner caps may be removed from the Cooktop and washed in s...

Reviews: