H1-58-01-02-Ä
13
For internal use only
6.2
Calibration modus on exchanging the electronics unit
Automatic calibration
Clean the pane.
Remove fingerprints and any other soiling with Sidolin or a similar product.
Before switching on the circuit breakers again, the balancing device is positioned on the control in such
a way that no sensor is covered by the spacers.
Now the circuit breakers can be switched on again.
First the current status of the software is indicated in the segment display.
After approx. 2 minutes (
the electronics unit twice counts up to 60 seconds in the left segment indicator
)
4 successive acoustic signals will sound to signal that calibration is completed.
In this status the ESW 308.6 can be operated as usual again. It is recommended, however, to check
each sensor again.
See the operation manual of the honeycomb present.
Balancing aid: product no. 340252