10.1.2 EMWK 9800.0
Error specification
Error code
Possible causes of faults
Possible repair measures
Oven temperature probe highly resistant
E1
Oven temperature probe defect
Replace temperature probe
Relay board defect
Replace relay board
E1 unstable
MW leakage radiation (leak in the oven, etc.)
Replace appliance
Low-resistance oven temperature
E2
Oven temperature probe defect
Replace temperature probe
Relay board defect
Replace relay board
E2 unstable
MW leakage radiation (leak in the oven, etc.)
Replace appliance
Microwave oven operation, start sequence:
Magnetron does not start
E9
See fault-tracing tree
Microwave oven operation, start sequence: con-
verter does not react when activated
E10
Microwave oven operation, run mode:
MW defect during operation
E11 Converter
defect
Replace
converter
Magnetron defect
Replace magnetron
ROM fault
E16
Relay board defect
Replace relay board
EEPROM fault
E17
Relay board defect
Replace relay board