7.3
Testing the converter
1. Start up the test program.
2. Turn the temperature knob clockwise (three lock-ins).
Display:
Test converter
Water Load
3. Press the start button.
Test is carried out at 900W for 2 minutes.
Only carry out the test with the door closed!!!
Once the test has been completed a corresponding error message will be shown in the clock display.
Possible error messages are indicated under ”10. Troubleshooting” on page 23 .
7.4
Testing the control elements
7.4.1
EMWK 9600.0
Start up the test program.
Buttons to press
Symbols
shown
Clock display
Press the clock button once
LED_CLOCK
02
Door contact open
None
00:
Door contact closed
None
:00
MW power button 90 W
LED_MW1
11:11
MW power button 180 W
LED_MW2
22:22
MW power button 360 W
LED_MW3
33:33
MW power button 600 W
LED_MW4
44:44
MW power button 900 W
LED_MW5
55:55
Start button
None
0S:00
Stop button
None
0S:01 + and error signal (no time limit)