background image

14

Service Manual

For internal use only

Once the right configuration number is chosen, then pressing CHILD LOCK it will be confirmed and
downloaded inside the hob. The decimal dot of zone 2 blinks for a few seconds, while downloading.
Finally the USIF goes, automatically, to checking mode. By using ON/STAND BY button the menu is left
and the appliance will start its usual behaviour.

9.2.4

Configuration numbers and models

Once inside “Configuration mode” (CO), in case it is not possible to configure the
system because one of the boards refuses to accept the configuration, a failure “EE”
will be displayed for 5 seconds on the displays instead of “CO”, and a constant beep
will be emitted. Then the menu CO is possible to be entered again.

IMPORTANT !!!
After leaving Configuration Mode it is compulsory to reset the USIF in order to update
the stored configuration. In order to do that, you have to UNPLUG the hob from the
mains and wait for ten seconds before plugging it again.

After plug-in, in case there is a wrong configuration, we will see an error message “F XX”.

Config. no.

Model

Features

35 

IR / IT 641 

Hob with 4 cooking zones with timer 

45 

IR / IT 631 

Hob with 3 cooking zones (145+210+dual right) with timer 

47 

IRC 631 

Hob with 3 cooking zones (145+180+dual right) with/without timer 

48 

IR 630 

Hob with 3 cooking zones (145+180+dual right) with timer 

Summary of Contents for EKI 6130

Page 1: ...Induction hobs EKI 6130 6140 G1 Series Configuration and failure codes...

Page 2: ...Manual H1 53 01 Responsible Dieter Rutz K PPERSBUSCH HAUSGER TE AG Email dieter rutz kueppersbusch de Tel 0209 401 732 Customer Service Fax 0209 401 743 Postfach 100 132 Date 25 08 2010 45801 Gelsenk...

Page 3: ...layouts 6 6 Communication and connectors 7 7 System failures 8 7 1 Failure types 8 8 Failure codes 10 9 Configuration and test mode 11 9 1 Access to the Test and configuration Mode 11 9 2 Main menu 1...

Page 4: ...rly connected The ground wire resistance must not exceed that specified in the standard It is vital for ensuring the safety of persons and the functioning of the appliance On completion of repairs an...

Page 5: ...stic electrical appliances The operating principle is innovating Contrary to other cooking modes it is the container itself which heats and not the hob You put a saucepan down and this is sufficient t...

Page 6: ...f the detection recovery method At no greater than 10 seconds duration of the aforementioned power line disruption the disturbance will be considered a power failure A line disturbance meeting the cri...

Page 7: ...figuration buzzer Option 6 3 induction zones with keys on each zone zone 1 is missing here no timer child lock led to indicate the lock state IR port for configuration buzzer 6 Communication and conne...

Page 8: ...en a long beep is emitted Every failure type 1 that concerns one cooking zone only is only shown on the display of that cooking area Supposing to have the error coded with F21 on zone 1 then it will b...

Page 9: ...ow the user to utilize the whole hob When this type of failure occurs the USIF switches OFF all the cooking zones present on the hob sending down power levels equal to zero and it becomes insensitive...

Page 10: ...ultaneously touching and keys corresponding to that heater Code Type of failure Failure description Possible solution F12 1 IPC error low current in coil If persistent change IPC F21 External cause Ma...

Page 11: ...g the FIRST connection to power supply In such situation USIF needs some seconds to calibrate its keys and strong lights might disturb this activity 9 1 Access to the Test and configuration Mode 1 UNP...

Page 12: ...2 Main menu Once the right test sequence is introduced the USIF will enter the main menu providing the following options Configuration Checking To show these two letters the USIF will use the cooking...

Page 13: ...onfiguration menu it is necessary to press the Child lock button when CO is shown on the displays Once this configuration sub menu CO is acceded 70 different hob configurations already stored in the E...

Page 14: ...a failure EE will be displayed for 5 seconds on the displays instead of CO and a constant beep will be emitted Then the menu CO is possible to be entered again IMPORTANT After leaving Configuration M...

Page 15: ...rtant remarks that shall be considered when changing some parts of the system Next picture shows a general view of the induction module together with the name given to each component 10 1 General view...

Page 16: ...s to TC as shown in the next picture Connection of communication cables Each time a TC and or IPC s is are changed during service intervention it is compulsory to perform the configuration of the hob...

Page 17: ...is to be connected Configuration SS has same size and kind of res caps small The small pair of res caps is intended to drive coils of diameter 145 180 or dual 260 A SS IPC has to be used when coils di...

Page 18: ...identify address 2 the IPC placed in position B MUST include a jumper in connector J6P as shown in the figure on page 13 No jumper placed means address 1 so IPC placed in position A needs no jumper I...

Page 19: ...d on the IPC board while the temperature sensor is connected in its connector near the towers Substitution of a dual coil is described in the following section 10 5 2 Substitution of a dual coil One I...

Page 20: ...EKI 6140...

Page 21: ......

Page 22: ......

Page 23: ...EKI 6130...

Page 24: ......

Page 25: ......