background image

Summary of Contents for ZGF 326

Page 1: ......

Page 2: ...sequent modifications During Operation About Installation Cleaning and Manteinance It is mandatory that all operations required for the installationarecarriedoutbyaqualifiedorcompetent person in accordance with existing rules and regulations Disconnect the appliance from the electrical supply before carrying out any cleaning or manteinance work Ensure a good ventilation around the appliance A poor...

Page 3: ...the symbol z Always turn the flame down or put it out before taking the pans off the burner USING THE HOB CORRECTLY To ensure maximum burner efficiency it is strongly recommended that you use only pots and pans with a bottom fitting the size of the burner used so that flame will not spread beyond the bottom of the vessel see the tablebeside It is also advisable as soon as a liquid starts boiling t...

Page 4: ...e pan supports are dishwasher proof If the marks are particularly difficult to remove use common non abrasive cleaners or specific products Never use steel wool pads or acids In models provided with electric ignition this feature is obtained through a ceramic candle and a metal electrode Fig 1 lett C Keep these components well clean to avoid difficult lighting and check that the burner crown holes...

Page 5: ...pressure of the appliance must correspond to the recommendedvalues Theadjustableconnectionisfixedtothecomprehensive ramp by means of a threaded nut G 1 2 Interpose the sealing between the components as shown in Fig 3 Screw the parts without forcing adjust the connection in the required direction and tighten everything The adjustable connection allows the feeding pipe to be situated in the site pur...

Page 6: ...iance and the electricity supply with a minimum gap of 3 mm between the switch contacts and of a type suitable for the required load in compliance with the current rules The connection cable has to be placed in order that in each part it cannot reach a temperature 90 C higher than the room temperature The brown coloured phase cable fitted in the terminal blockcontactmarkedwith L mustalwaysbeconnec...

Page 7: ...ig 7 FO 0392 ADJUSTMENT OF MINIMUM LEVEL To adjust the minimum level of the burners proceed as follows Light the burner Turn the knob on the minimum position Remove the knob With a thin screwdriver adjust the by pass screw see Fig 8 a If changing from natural gas to LPG completely tighten clockwise the screw until a small regular flame is obtained Finally check the flame does not go out when quick...

Page 8: ...t overlapping place the hob in the cut out taking care of its centring fix the hob with the relevant screws Fig 11 The traction of the screws is able to trace the sealing any excess of which can then be easily removed The edge of the hob forms a double labyrinth seal which provides a total guarantee against infiltration of liquids If several function are to be combined 2 burners hob fish kettle bu...

Page 9: ......