INJECTORS REPLACEMENT

• Remove the pan supports.

• Remove the burner's caps and crowns.

• With a socket spanner 7 unscrew and remove the

injectors (Fig. 7), and replace them with the ones
required for the type of gas in use (see 

table 2

).

• Reassemble the parts, following the same procedu-

re backwards.

• Replace the rating label (placed near the gas supply

pipe) with the relevant one for the new type of gas
supply. You can find this label in the package of the
injectors supplied with the appliance.

Should the feeding gas pressure be different or
variable compared with the required pressure, an
appropriate pressure adjuster must be fitted on the gas
supply pipe, in compliance with the rules in force.

6. Adaptation to different types of gas

Fig. 7

FO 0392

ADJUSTMENT OF MINIMUM LEVEL

To adjust the minimum level of the burners, proceed as
follows:

Light the burner.

Turn the knob on the minimum position.

Remove the knob.

With a thin screwdriver, adjust the by-pass screw
(see Fig. 8 - "

a

"). If changing from natural gas to

LPG, completely tighten clockwise the screw, until a
small regular flame is obtained.

Finally check the flame does not go out when quickly
turning the knob from the maximum position to the
minimum position.

This procedure can easily be carried out, anyhow the
hob has been positioned or built in the working top.

BURNER

NORMAL

REDUCED

NORMAL

POWER

POWER

POWER

kW

kW

NATURAL GAS

LPG

G20 - 20 mbar

28-30/37 mbar

inj. 1/100

m

3

/h

inj. 1/100 g/h - G30 g/h - G31

Auxiliary (small)

1

0,33

70

0,095

50

73

71

Natural gas :

Rapid (big)

3

0,65

119

0,286

86

203

200

LPG : 2,8

  Burner

Ø By-pass

in 1/100

of mm.

  Auxiliary

28

  Rapid

40

Table 1 : By-pass diameters

Table 2 : injectors

Fig. 8

by-pass screw

Summary of Contents for ZGF 326

Page 1: ......

Page 2: ...sequent modifications During Operation About Installation Cleaning and Manteinance It is mandatory that all operations required for the installationarecarriedoutbyaqualifiedorcompetent person in accordance with existing rules and regulations Disconnect the appliance from the electrical supply before carrying out any cleaning or manteinance work Ensure a good ventilation around the appliance A poor...

Page 3: ...the symbol z Always turn the flame down or put it out before taking the pans off the burner USING THE HOB CORRECTLY To ensure maximum burner efficiency it is strongly recommended that you use only pots and pans with a bottom fitting the size of the burner used so that flame will not spread beyond the bottom of the vessel see the tablebeside It is also advisable as soon as a liquid starts boiling t...

Page 4: ...e pan supports are dishwasher proof If the marks are particularly difficult to remove use common non abrasive cleaners or specific products Never use steel wool pads or acids In models provided with electric ignition this feature is obtained through a ceramic candle and a metal electrode Fig 1 lett C Keep these components well clean to avoid difficult lighting and check that the burner crown holes...

Page 5: ...pressure of the appliance must correspond to the recommendedvalues Theadjustableconnectionisfixedtothecomprehensive ramp by means of a threaded nut G 1 2 Interpose the sealing between the components as shown in Fig 3 Screw the parts without forcing adjust the connection in the required direction and tighten everything The adjustable connection allows the feeding pipe to be situated in the site pur...

Page 6: ...iance and the electricity supply with a minimum gap of 3 mm between the switch contacts and of a type suitable for the required load in compliance with the current rules The connection cable has to be placed in order that in each part it cannot reach a temperature 90 C higher than the room temperature The brown coloured phase cable fitted in the terminal blockcontactmarkedwith L mustalwaysbeconnec...

Page 7: ...ig 7 FO 0392 ADJUSTMENT OF MINIMUM LEVEL To adjust the minimum level of the burners proceed as follows Light the burner Turn the knob on the minimum position Remove the knob With a thin screwdriver adjust the by pass screw see Fig 8 a If changing from natural gas to LPG completely tighten clockwise the screw until a small regular flame is obtained Finally check the flame does not go out when quick...

Page 8: ...t overlapping place the hob in the cut out taking care of its centring fix the hob with the relevant screws Fig 11 The traction of the screws is able to trace the sealing any excess of which can then be easily removed The edge of the hob forms a double labyrinth seal which provides a total guarantee against infiltration of liquids If several function are to be combined 2 burners hob fish kettle bu...

Page 9: ......

Reviews: