Service Manual
15
For internal use only
7.9
Sensors
The sensors measure
•
the temperature of the steam generator
•
the temperature in the oven
They are automatically recognised by a microprocessor; faulty wiring
cannot occur.
NTC technical data:
•
55k
Ω
at 20°C
•
4.7k
Ω
at 90°C
Temperature sensor resistance data
Heating element (blue-yellow), spare-part no. 531242 (board on the left)
Oven (red-white), spare-part no. 531241 (board on the right)
Temperature
Resistance
20°C
58k
Ω
30°C
39k
Ω
40°C
32k
Ω
50°C
25k
Ω
60°C
18k
Ω
70°C
12k
Ω
80°C
9k
Ω
90°C
7k
Ω
100°C
5k
Ω
110°C
3.5k
Ω
120°C
2.5k
Ω
130°C
2k
Ω
7.10
Lighting
The light bulb is located inside the oven, at the back on the right-hand side.
Disconnect your steam oven from the mains prior to
carrying out any work on the lamp in order to avoid electric
shocks.
•
Turn the glass cover a quarter of a turn in an anti-clockwise direction.
•
Turn the light bulb anti-clockwise to screw it out.
•
Change the light bulb, replace the glass cover and make sure that
the seals are in the right position.
•
Re-connect your steam oven to the power supply.
Technical data:
•
15W - 300°C
•
220 - 240V
•
E14 base