8
Service Manual
For internal use only
•
Repeat the test by inserting the test prod into pins 3
and 6 of the 9 pole connector, placed in the downdraft
lower body.
•
Repeat the test by inserting the test prod in CN111
connector of the main board, placed in the electrical
system box.
•
If the button must be replaced, it is necessary to use
an original spare part.
2.5
Check if the panel is unhooked
If the extractable unit is closed and the panel accidentally unhooks , causing the opening of the contact
of the filters panel position , it is necessary to hook it again in order to restore operation.
•
Disconnect the downdraft from the power supply.
Button released =
Contact open
Button pressed =
Contact closed