5.
The extractable unit opens, but the suctioning system
does not work at any speed
5.1
Check if the 6-pole suctioning unit connector or the sem
power pack connector are connected properly
•
See Chapter “Check if the suctioning unit 6-pole connector wires in the electrical system board are
connected properly” on page 13.
5.2
Replace the main electrical system board
•
See “Replace the electrical system board” on page 10.
5.3
Replace the suctioning unit (if the downdraft is equipped with
an internal motor)
•
See “Replace the suctioning unit in case of internal motor version” on page 16.
5.4
Replace the external (sem) power pack if the downdraft is
equipped with an external motor
•
See chapter “Replace the sem external power pack in case of external motor (em) version” on
page 17.
6.
The suctioning system works but the extractable unit
does not open
6.1
Check if the electrical system connectors are connected
properly
•
See “Check if the red power button is in on position” on page 5.
6.2
Check the internal connection of the actuator
•
Remove the suctioning unit or the pipe flange in case of external motor version (see “Check if the
red power button is in on position” on page 5).