Starting the BONA DCS25 and Collecting Dry Dust
NOTE:
If hand tool with a power consumption of more than 1500 W is
connected, the total current consumption will exceed approx.
13 A, which is often the normal fuse size.
ALWAYS turn off the hand tool before you turn off the machine on the switch.
Automatic start/stop “O” = the automatic start/stop is not activated. The vacuum cleaner will start when you set the main switch
(red) on “I”.
Automatic start/stop “O” = the automatic start/stop is not activated. The vacuum cleaner will start when you set the main switch
(red) on “I”.
When the automatic start/stop is activated “I” and a hand tool is connected to the electrical outlet, the machine will start when
the hand tool is started.
BONA DCS25 can be used with tools with a power
consumption of 2000 W (Country code EU). 1450 W
corresponds to a current consumption of approx. 6,3A.
Information can be found on the data plate of the
machine.
The automatic start/stop is activated with the black switch on the motor top. When
the automatic start/stop is activated, the machine will not start when you push the
red switch. The machine will not start until the connected hand tool is started.
Set the red switch on “I” to start the vacuum cleaner (when “Automatic” is not
needed or no tool connected).