Installation Instruction DF PROFI PCIe

4 / 7

2 Safety Instructions

 WARNING

Disregarding this warning may result in damage to equipment and/or
serious personal injury.

Only qualified personnel may start up and operate this device. According to
the safety instructions in this text, qualified personnel are persons who are
authorized to start up, to ground, and to mark devices, systems, and
equipment according to the standards of safety technology.

In addition, these persons must be familiar with all warning instructions and
maintenance measures in this text.Folgen

 WARNING

The DF PROFINET IO PCI board is designed exclusively for PELV
operation according to EN 60950/EN 60204/VDE 0805-1.

NOTICE

Shielding

The shielding ground of the connected twisted pair cables is electrically
connected to the female connector. When connecting network segments,
avoid ground loops, potential transfers, and voltage equalization currents
via the braided shield.

NOTICE

Electrostatic discharge!

The device contains components that can be damaged or destroyed by
electrostatic discharge. When handling the device, observe the necessary
safety precautions against electrostatic discharge (ESD), in accordance
with

EN 61340-5-1 and EN 61340-5-2, as well as

IEC 61340-5-1 and IEC 61340-5-2.

Safety Instructions

Summary of Contents for DF PROFINET IO PCI

Page 1: ...Installation Instruction DF PROFINET IO PCIe V 1 6 02 04 2019 ...

Page 2: ... www kunbus de The KUNBUS GmbH shall be liable exclusively to the extent specified in General Terms and Conditions www kunbus de agb html The contents published in this user manual are protected by copyright Any reproduction or use for the in house requirements of the user is permitted Reproduction or use for other purposes are not permitted without the express written consent of the KUNBUS GmbH C...

Page 3: ...UNBUS GmbH Table of Content Installation Instruction DF PROFI PCIe iii Table of Content 1 Disclaimer 2 2 Safety Instructions 4 3 Installation on the Board 5 4 Description of the LEDs 6 5 Technical Data 7 ...

Page 4: ...res in this text Folgen WARNING The DF PROFINET IO PCI board is designed exclusively for PELV operation according to EN 60950 EN 60204 VDE 0805 1 NOTICE Shielding The shielding ground of the connected twisted pair cables is electrically connected to the female connector When connecting network segments avoid ground loops potential transfers and voltage equalization currents via the braided shield ...

Page 5: ...ceed as follows Switch off your PC and unplug the mains plug Remove the screws of the PC cage and lift off the cover If necessary please see also the operating instructions of your PC Select a free PCI slot Remove the slot cover and plug the DF board into the determined slot Pay attention to a proper adjustment of the board in the guidance avoid canting Screw down the board Fix the cover again and...

Page 6: ...INET IO stopped Red Operation as PROFINET IO Controller on Ethernet Interface 1 on PROFINET IO Failure min one device not connected to the PROFINET IO network or with external dia gnosis off No PROFINET IO Failure Operation as PROFINET IO Device on Ethernet Interface 2 on PROFINET IO Failure No active PROFINET IO con troller connected off No PROFINET IO Failure Description of the LEDs ...

Page 7: ... 1 ms Processor 1 3 GHz Freescale PowerQUICC III Memory 1 GB DDR II 32 MB Flash Memory PCI Interface PCI Rev 2 2 32 Bit 5 V and 3 3 V supported Ethernet Interface RJ45 100 Base T X Data Size of Process Image 16 KB Power Consumption Typical 7W Ambient Temperature Range 0 C 55 C Dimensions 188 mm x 126 mm x 20mm Table 1 Technical Data Technical Data ...