1 Disclaimer

© 2019 KUNBUS GmbH, Denkendorf (Deutschland)

The contents of this user manual have been prepared by the KUNBUS
GmbH  with  the  utmost  care.  Due  to  the  technical  development,  the
KUNBUS GmbH reserves the right to change or replace the contents
of  this  user  manual  without  prior  notice.  You  can  always  obtain  the
latest version of the user manual at our homepage: www.kunbus.de

The KUNBUS GmbH shall be liable exclusively to the extent specified
in General Terms and Conditions (www.kunbus.de/agb.html).

The contents published in this user manual are protected by copyright.
Any reproduction or use for the in-house requirements of the user is
permitted. Reproduction or use for other purposes are not permitted
without  the  express,  written  consent  of  the  KUNBUS  GmbH.
Contraventions shall result in compensation for damages.

Trademark protection

– KUNBUS is a registered trademark of the KUNBUS GmbH

– Windows® and Microsoft® are registered trademarks of the Microsoft,

Corp.

Disclaimer

Summary of Contents for DF PROFINET IO PCI

Page 1: ...Installation Instruction DF PROFINET IO PCIe V 1 6 02 04 2019 ...

Page 2: ... www kunbus de The KUNBUS GmbH shall be liable exclusively to the extent specified in General Terms and Conditions www kunbus de agb html The contents published in this user manual are protected by copyright Any reproduction or use for the in house requirements of the user is permitted Reproduction or use for other purposes are not permitted without the express written consent of the KUNBUS GmbH C...

Page 3: ...UNBUS GmbH Table of Content Installation Instruction DF PROFI PCIe iii Table of Content 1 Disclaimer 2 2 Safety Instructions 4 3 Installation on the Board 5 4 Description of the LEDs 6 5 Technical Data 7 ...

Page 4: ...res in this text Folgen WARNING The DF PROFINET IO PCI board is designed exclusively for PELV operation according to EN 60950 EN 60204 VDE 0805 1 NOTICE Shielding The shielding ground of the connected twisted pair cables is electrically connected to the female connector When connecting network segments avoid ground loops potential transfers and voltage equalization currents via the braided shield ...

Page 5: ...ceed as follows Switch off your PC and unplug the mains plug Remove the screws of the PC cage and lift off the cover If necessary please see also the operating instructions of your PC Select a free PCI slot Remove the slot cover and plug the DF board into the determined slot Pay attention to a proper adjustment of the board in the guidance avoid canting Screw down the board Fix the cover again and...

Page 6: ...INET IO stopped Red Operation as PROFINET IO Controller on Ethernet Interface 1 on PROFINET IO Failure min one device not connected to the PROFINET IO network or with external dia gnosis off No PROFINET IO Failure Operation as PROFINET IO Device on Ethernet Interface 2 on PROFINET IO Failure No active PROFINET IO con troller connected off No PROFINET IO Failure Description of the LEDs ...

Page 7: ... 1 ms Processor 1 3 GHz Freescale PowerQUICC III Memory 1 GB DDR II 32 MB Flash Memory PCI Interface PCI Rev 2 2 32 Bit 5 V and 3 3 V supported Ethernet Interface RJ45 100 Base T X Data Size of Process Image 16 KB Power Consumption Typical 7W Ambient Temperature Range 0 C 55 C Dimensions 188 mm x 126 mm x 20mm Table 1 Technical Data Technical Data ...