Kuhse KEA 101 NSTR Service Manual Download Page 4

 

        SA101NX3-E                                                      - 4 / 8 -                                                        07-01-25 

 

 

P

ARAMETERISATION

 

 

Menu structure *) 

 

Group 0 

 

Group 

 

Group 2 

 

Group 3 

 

Group 4 

 KEA 101 NSTR 
   KUHSE GmbH 

     ACTUAL VALUES 

 

  ENCODING OF 

           ALARMS

 

MAINS VOLTAGE 
          MONITOR 

     GENERATOR 

VOLTAGE MONITOR 

 

      COUNTERS 

 

   

 

 

  GEN.CURRENT 

        MONITOR 

 

 

 

 

 

 

 

 

 

Group 5 

 

Group 6 

 

Group 7 

 

Group 8 

 

Group 9 

ANALOGUE 
         INPUTS 

  SPEED MONITORING 

 SPEED GOVERNOR 

  START-STOP 

      FUNCTIONS 

 

PARAMETER FOR 
  MAINS <> GEN. 

  RELAY / LED 

      FUNCTIONS 

ANALOGUE 
         OUTPUTS 

   

  BATTERY VOLTAGE 

         MONOTOR 

 

 

   

 

 

 

 

ADDITIONAL 

       PARAMETER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Group 10 

 

Group 11 

 

Group 12 

 

Group 

13  Group 

14 

 

  FREQUENCY CONTROL 

VOLTAGE CONTROL 

  ANALOGUE VALUES 

        VIA CAN 

 

THERE ARE NO 
  CURRENT ALARMS 

  THERE ARE NO 

  CURRENT ALARMS 

 
*) Since software version 8. 
 
The functions and parameterisation are described in  

 

PA100V00-E, F

UNCTIONS AND 

P

ARAMETERISATION

 KEA 101- 112.    

 

This document contains all possible functions featured in the KEA Series 101-112. Please note however, that 
only those functions, listed in the Operation manual, are actually implemented. The P

ARA

W

IN

 

parameterisation program also shows only the parameters that are possible for the particular control unit. 

 

Group Function  Section 

in 

F

UNCTION AND 

P

ARAMETERISATION

 

Encoding of alarms 

Alarm monitoring 

Mains voltage monitor 

Voltage monitor 

Generator voltage monitor 

Voltage monitor 

Generator current monitor Current 

monitor 

Analogue inputs 

Analogue interface 

Analogue outputs 

Analogue interface 

Speed monitoring, speed governor 

Speed signals and governor 

Speed governor 

Speed signals and governor 

7 Start-stop 

functions 

Parameter for start and stop 

Battery voltage monitor  

Additional parameters 

Additional parameters 

Additional parameters 

Parameters for mains <> generator 

Transfer mains – generator supply 

Relay / LED functions 

Parameterisation of relays 

11 Frequency 

control 

Synchronisation 

11 Voltage 

control 

Synchronisation 

 

Connection of KEA and RZ 

Connection 

 

Operation Manual 

See TA101NX3-E 

 
 

 
 

Changes without further notice reserved.

 

Summary of Contents for KEA 101 NSTR

Page 1: ...connection to any other metal parts The supply voltage can be set to 12 or 24 V DC with a switch on the RZ 071 D When the supply voltage of the control unit has been switched off you must wait at least 20 seconds before applying it again All coils must be fitted with reverse diodes to prevent high voltage peaks All other coils or inductive loads must also be fitted with suppressor elements The sam...

Page 2: ...it has been switched off you must wait at least 20 seconds before applying it again The negative pole of the battery must be grounded at the input terminal of the switchboard The minimum conductor cross section is 10 mm2 The supply voltage can be set to 12 or 24 V DC with a switch on the RZ 071 D The screens of the analogue input wiring must be connected to the earth screws on the KEA cover and mu...

Page 3: ...ied The chosen parameter cannot be deselected now 5 Select the figure or letter of the parameter that you want to modify with the and cursor keys Numerical parameters can be increased or decreased by increments of 1 with the and buttons Press the same buttons to negate parameters that are displayed with a letter signs alarm coding etc 6 Press OFF and ALARM OFF together to store the displayed param...

Page 4: ...at only those functions listed in the Operation manual are actually implemented The PARAWIN parameterisation program also shows only the parameters that are possible for the particular control unit Group Function Section in FUNCTION AND PARAMETERISATION 2 Encoding of alarms Alarm monitoring 3 Mains voltage monitor Voltage monitor 4 Generator voltage monitor Voltage monitor 4 Generator current moni...

Page 5: ...wo programmable modes for this input input always active or input only active along with a mains voltage failure If an active command is stated the start of genset will be initiated and the load will be transferred from mains to generator supply in the operation mode AUTO If the genset is already running in TEST or AUTO mode or was started by the signal REMOTE START WITHOUT LOAD TRANSFER the gener...

Page 6: ... fails To switch off the generator breaker again both signals terminals 18 and 25 must be cut Terminal 26 External command GENERATOR OFF If a command is applied here the generator CB is immediately switched off and remains off as long as the signal is applied Terminal 27 Not used This terminal can be used as an alarm input Terminal 28 Not used This terminal can be used as an alarm input Terminal 2...

Page 7: ...ich can be fitted with interface cards for ο PT 100 PT1000 ο Current loops ο 0 10 V DC ο Thermocouple NiCr Ni ο Temperature and pressure VDO sensor ο Battery charging current Two analogue outputs 0 20 mA or 0 10 V Under development Relay unit RZ 071 D Device for attachment on a mounting rail dimensions depth 300 x 100 x 90 mm Weight approx 0 7 kg can be installed wherever required Protection class...

Page 8: ...400 Volt N 5 230 400 Volt 3 x 400 Volt N 6 3 x 400 Volt 3 x 100 Volt N 7 3 x 400 Volt 230 400 Volt N 8 3 x 400 Volt 3 x 400 Volt N 9 Special voltage or frequency N 0 CT 1 A N 2 CT 5 A N 3 Special voltage or current measurement N 0 Example Control unit for emergency power plants mains and generator voltage 230 400 V current transformer of generator 5 A The order number is 2A101N53 Changes without f...