Step 4.
Check that there is no longitudinal play on the shaft.
Check that the shaft can be rotated by hand.
If the shaft does not rotate, remove shim ring and repeat check.
If the longitudinal play remains, add a shim ring and repeat check.
Step 5.
Reinstall O-ring (1).
Reinstall spacer (2).
Reinstall oil seal (3).
Knife not parallel to anvil.