Step 15- Place Spacer

1. Place the small spacer block (M111-03) so that it is 
resting on the bottom rail approximately in the position
as shown below. This will be used to rest the door 
glass in position while fitting.

Step 14 - Fully Insert Push-In Channels

1. Remove the push-in channels previously 
inserted in step 3 and 8.

Push-in channel can be removed, by 
inserting tool (M305-01) supplied to pull the 
channel out at top.

2. Ensure outer edge of the Glass Panels 
are vertical, as shown, using spirit level. 
Make sure the rails are also level.

3. Fully insert the push-in channel (black 

strip towards glass) against the glass, 
starting from the bottom, insert into wall 

posts. Ensure they are both fully inserted 
so that the channel is flush with the surface 
of the wall post along the entire height.

Drawn lines on the glass panels
should not be visible beyond

the wallposts after fitting

push-in channels.

Step 10 - Fit Bottom Rail to Fixed Panels, Determine Opening Side

1. Acquire one of the rails. Outer extrusion to be on the outside of the glass. Line up the 2 holes on the rail with 2 slot/holes at the bottom of the glass.Ensure flange 
on rail is in contact with the bottom edges of the glass panel. Highlighted in the detailed diagram below.

2. Secure the rail with M144-02-AG using No.6x19 CSK. Apply to the end you intend the door to pivot/hinge from. Secure the opposite side with SF-BIF-CLMP-998 
using M6x30 CSK.

Step 11 - Fit Top Rail to Fixed Panels

1. Acquire the remaining last rail. Outer extrusion to be on 
the outside of the glass. Like step 7, line up the 2 holes on 
the rail with 2 slot/holes at the top of the glass. Ensure flange 
on rail is in contact with the top edges of the glass panel. 
Highlighted in the detailed diagram below.

2. Secure the rail with M144-02-AG using No.6x19 CSK. 
Apply to the end you intend the door to pivot/hinge from. 
Secure the opposite side with SF-BIF-CLMP-998 using 
M6x30 CSK.

Step 12 - Set Guide Stoppers

1. Use the 2mm allen key provided to loosen the guide stopper. Once loosened ‘slide’ to the side 
with the M144-02-AG. Re-tighten once the guide is in a position similar to the diagram below. Do 
this for both bottom and top rail. Guides need to be on the same side.

Step 12 - Level Bottom Rail

1. Often shower trays have 

different angled top faces, in 
order to help keep the frame 

supported use the ‘Shim (M193-
01)’ supplied. On the inside of 

the enclosure measure the gap 
between the bottom of the rail 
and top of the tray, select the 
height required from the shim 
strip supplied, break off and 

insert under rail. The shim will be 
concealed by silicone sealant later.

Inside view

Inside view

Inside view

Inside view

Inside view

Inside view

Inside view

Summary of Contents for Pinnacle 8 CENTREFOLD 800

Page 1: ...mix of white vinegar and water works well DO NOT use strong detergents abrasive cleaners or abrasive scrubbing equipment for cleaning these can damage the coating DO use a squeegee to remove remaining droplets of water from glass after showering any build up of residue can be removed easily using an appropriate cleaner and agitation from soft cleaning equipment Cleaning General Kudos LifeShield Gl...

Page 2: ... DOOR PACK A 800 P8CF80P1 P8CF80P2 770 to 790 900 P8CF90P1 P8CF90P2 870 to 890 1000 P8CF100P1 P8CF100P2 970 to 990 PRODUCT PACK CODES DIMENSIONS mm CENTRE FOLD SIDE PANEL PACK B 800 P8CF2SP80 770 to 790 900 P8CF2SP90 870 to 890 ENCLOSURE HEIGHT 2000mm 26mm A 26mm A LEFT HAND INSTALLATION RIGHT HAND INSTALLATION ...

Page 3: ...lpost is vertical 4 Position side panel wall post 16mm in from front edge of the tray as shown Repeat the above steps Insert screw heads into the wizard tool supplied to help locate screws into wall plugs Then tighten with pozi head screwdriver 1 Take note of label on glass This surface to outside this will determine which is the bottom edge of your installation 2a For 800 Side Panel Unit acquire ...

Page 4: ...ls Step 4 Fit Corner Joint Seal 1 Acquire the PlexRF 018 06 from the Side Panel Pack From starting at the bottom press this over the glass edge ensuring that it is fully seated over the entire length Position as shown If tight lubricate corner seal and glass edges with a damp clean cloth to ease fitment the water will evaporate over a short period Do not use silicone spray or any other substance o...

Page 5: ...ram below 2 Secure the rail with M144 02 AG using No 6x19 CSK Apply to the end you intend the door to pivot hinge from Secure the opposite side with SF BIF CLMP 998 using M6x30 CSK Step 11 Fit Top Rail to Fixed Panels 1 Acquire the remaining last rail Outer extrusion to be on the outside of the glass Like step 7 line up the 2 holes on the rail with 2 slot holes at the top of the glass Ensure flang...

Page 6: ...ottom hinge and fully tighten Open the door and discard the spacer block 1 Acquire SF BIF SLID 998 from the installation pack and disassemble Insert the top slide on the closing side of the door into the rail by tilting the slide and lowering the rectangular slide into the track of the rail Tilt the slide and offer it into the rail as shown 2 Now push up and into the Slide will run smoothly in the...

Page 7: ...nclosure will not leak under normal showering use ie when the shower head is in it s normal showering position N B Using the shower head to clean rinse down the enclosure does not constitute normal showering use Step 20 Fitting the Door Seals 1 There are two longer seals 2 x 1940mm and one shorter 1 x 1926mm similar to the diagram shown The longer seals fit the the fixed glass panels either side o...

Reviews: