Hydraulic Crimping Tools
12
KuDos Mechanical
Troubleshooting
The fitting cannot
be crimped:
Handle is stuck or
can’t release the
pressure:
Piston action is slow
or spongy:
•
1. One or more tool parts require repair. Replace
the parts immediately to prevent serious personal
injury or property damage.
•
2. Applied fitting is over-specification.
•
3. Insufficient hydraulic fluid. Follow steps on page
10 to add fluid.
•
4. The cylinder piston might be deformed after
crimping an off-center fitting, or from the tool
being used in a manner for which it was not
intended.
•
1. Clean the moving handle to remove impedi-
ments.
•
2. Pressure can be released by pressing down the
release lever manually.
•
3. Torsional spring is stuck: Contact your KuDos®
service representatives.
•
1. There is air in the hydraulic system. Follow steps
on page 10 to expel any air in the system.
•
2. Insufficient hydraulic fluid. Follow steps on page
10 to add fluid.