TILING ALLOWANCE

To overcome the width of the integral upstand of the shower tray, either method can be used

IMPORTANT: IF THE DIMENSIONS SHOWN ARE EXCEEDED THEN THE GLASS PANEL(s) WILL NOT FIT

APPLY FINISH TO WALLS

Fit tiles/shower panels to the walls and apply silicone sealant where tiles/panels meet tray at bottom

INSTALL WALK-IN SHOWER ENCLOSURE

The enclosure can be fitted to suit both right-hand and left-hand installations

Note: If you are installing the recess version (curved panel glass only), then please ignore any reference to the side 
glass panel and corner rail instructions

15

16

17

METHOD ‘A’

SPACER PANEL TO WALL

MUST NOT EXCEED 14mm

METHOD ‘B’

TRAY CHASED INTO WALL

MUST NOT EXCEED 14mm

CURVED PANEL

COVER CAP

WATER OUTLET

BODY

SIDE PANEL
COVER CAP

FINIAL TOP/

RAIL HOLDER

ASSEMBLY

RAIL WALL

BRACKET

SHROUD

SPACER COLLAR

ASSEMBLY

SHROUD

FINIAL BOTTOM

ASSEMBLY

CORNER ENCLOSURE / RIGHT HAND ACCESS 

UTILISING UNDER-TRAY WATER SUPPLY

RECESS ENCLOSURE / RIGHT HAND ACCESS

UTILISING OVERHEAD WATER SUPPLY

675mm 

(1400 tray)

500mm

Right-hand Access 
Tray shown

860mm 

(1700 tray)

(1400 & 1700 trays)

Summary of Contents for 1700

Page 1: ... tray has been installed i e when installing the tray directly onto a solid floor Install shower tray Apply finish to walls e g tiling Install shower enclosure Connect to flexible hose and fit Water Delivery Column THESE INSTRUCTIONS ARE TO BE LEFT WITH THE CONSUMER 1st 2nd 3rd 4th 5th 6th 7th KEY STAGES TO INSTALLATION INSTALLATION INSTRUCTIONS 1400 1700 KUDOS WALK IN ENCLOSURE Incorporating AQUA...

Page 2: ... Directly if unit is within reach B Via 15mm copper pipe if unit is not within reach IMPORTANT please take note of dimensions for exposed hose if not adhered to connection with the Water Outlet Body at a later stage will not be possible 13 14 RECESS LOCATION BUSH FOR CURVED GLASS PANEL CORNER LOCATION BUSH FOR CURVED GLASS PANEL LEFT HAND ACCESS TRAY RECESS LOCATION BUSH FOR CURVED GLASS PANEL COR...

Page 3: ...e installing the recess version curved panel glass only then please ignore any reference to the side glass panel and corner rail instructions 15 16 17 METHOD A SPACER PANEL TO WALL MUST NOT EXCEED 14mm METHOD B TRAY CHASED INTO WALL MUST NOT EXCEED 14mm CURVED PANEL COVER CAP WATER OUTLET BODY SIDE PANEL COVER CAP FINIAL TOP RAIL HOLDER ASSEMBLY RAIL WALL BRACKET SHROUD SPACER COLLAR ASSEMBLY SHRO...

Page 4: ...ocate screws into pre drilled holes TIP FIT CURVED GLASS PANEL Insert finial bottom assembly with inner cover removed into location bush Carefully insert glass panel into main channel and onto finial body SECURE CURVED GLASS PANEL Screw inner cover to finial bottom using 4mm Allen key provided ensuring the protective plastic hole washer is fitted over the screw Insert glazing seal to inside betwee...

Page 5: ...n wall bracket to wall and mark through fixing hole Drill 8mm plug and fix using No 12 s x 30mm long screw provided Refit top rail assembly and tighten all screws using 2 5mm 3mm Allen keys supplied ensuring that the shaped brass bush is fitted inside the top rail holder s FIT COVER CAPS Fit cover caps to top of channels using No 6 s x 10mm long screws provided FIT BOTTOM SEAL OPTIONAL Trim to len...

Page 6: ...aining 945mm long extension tube is not required for this water supply Make 25mm hole in ceiling directly above column Fit plug connector to BOTTOM of Water Outlet Body ensuring the rubber washer is fitted Feed flexible hose through extension tube cut tube to length if necessary top spacer collar assembly and 910mm long tube and connect hose to TOP of Water Outlet Body ensuring rubber washer is fi...