67
REGULAR CHECKS AND MAINTENANCE WORK
B
Checking Radiator Hoses and Clamps
To avoid personal injury or death:
A
Wait long enough for the radiator coolant to
cool down.
Check the coolant hoses for proper connection. This
check should be carried out every 200 hours or every 6
months, whichever comes first.
1. Should the hose clamps become loose or coolant
leaks, tighten the hose clamps properly.
2. Should the radiator hoses become swollen, aged or
cracked, they must be replaced and the hose clamps
tightened again properly.
B
Grease Swing Ball Bearing
1. Grease through the respective grease fitting. (at the
central fitting)
2. Grease at each 90 (1.58 rad.) position of the swing
frame.
Using the grease gun, apply 5 shots at every position.
B
Inspection and Cleaning Air Filter Element
Open the engine hood and remove the dust-cover. Take
out only outer element, clean the element, case interior
and reassemble. During reassembly, take care to install
the dust-cover so that its TOP mark (arrow) faces up-
wards. Do not remove the inner element.
A
Should the machine be used in extremely dusty areas,
the air filter element must be inspected and cleaned
more frequently than in the specified maintenance
periods.
A
The air filter has a dry element, keep free from oil.
A
Do not run the engine without the air filter.
(1) Hose clamp
(2) Radiator hose
(1) Grease fitting
(1) Inner element
(2) Outer element
(3) Dust-cover
(4) Clamps
Summary of Contents for U35-4
Page 16: ...SAFE OPERATION 8 6 DANGER WARNING AND CAUTION LABELS ...
Page 17: ... 9 SAFE OPERATION ...
Page 18: ...SAFE OPERATION 10 ...
Page 19: ... 11 SAFE OPERATION ...
Page 20: ...SAFE OPERATION 12 ...
Page 21: ... 13 SAFE OPERATION ...
Page 24: ...DEALER SERVICE 2 1 Engine serial No ...
Page 66: ...44 EXCAVATOR OPERATION ...
Page 114: ...92 LIFTING CAPACITY ...
Page 115: ...93 LIFTING CAPACITY ...