65
REGULAR CHECKS AND MAINTENANCE WORK
C
Battery Charging
To avoid personal injury or death:
A
When the battery is being activated, hydrogen
and oxygen gases in the battery are extremely
explosive. Keep open sparks and flames away
from the battery at all times, especially when
charging the battery.
A
When charging the battery, remove battery
vent plugs. (if equipped)
A
When disconnecting the cable from the battery,
start with the negative terminal first.
When connecting the cable to the battery, start
with the positive terminal first.
A
Never check battery charge by placing a metal
object across the posts.
Use a voltmeter or hydrometer.
1. To slow charge the battery, connect the battery
positive terminal to the charger positive terminal and
the negative to the negative, then recharge in the
standard fashion.
2. A boost charge is applied only to refillable type and is
only for emergencies. It will partially charge the battery
at a high rate and in a short time.
When using a boost-charged battery, it is necessary to
recharge the battery as early as possible.
Failure to do this will shorten the battery's service life.
3. The battery is charged if the indicator display turns
green from black.
4. When exchanging an old battery for a new one, a
battery of equal specification.
C
Direction for Storage
1. When storing the machine for long periods of time,
remove the battery from machine, adjust the
electrolyte to the proper level and store in a dry place
out of direct sunlight.
2. The battery self-discharges while it is stored.
Recharge it once every three months in hot seasons
and once every six months in cold seasons.
B
Greasing Swing Bearing Teeth
1. Pump grease with the grease gun through the grease
fitting.
2. Grease at each 90 (1.58 rad.) position of the swing
frame.
3. Fill with approx. 50g of grease (approx. 20 to 30
pumps with the grease gun at each position).
Distribute the grease over the teeth.
(1) Battery
Battery Type
Volts (V)
Capacity
GP24 (80D26R)
12
55 (at 5H.R(A.H))
Battery Type
Reserve
Capacity
(min)
Cold
Cranking
Amps
Normal
Charging
Rate (A)
GP24 (80D26R)
133
582
6.5
(1) Grease fitting (for swing bearing teeth)
Summary of Contents for U35-4
Page 16: ...SAFE OPERATION 8 6 DANGER WARNING AND CAUTION LABELS ...
Page 17: ... 9 SAFE OPERATION ...
Page 18: ...SAFE OPERATION 10 ...
Page 19: ... 11 SAFE OPERATION ...
Page 20: ...SAFE OPERATION 12 ...
Page 21: ... 13 SAFE OPERATION ...
Page 24: ...DEALER SERVICE 2 1 Engine serial No ...
Page 66: ...44 EXCAVATOR OPERATION ...
Page 114: ...92 LIFTING CAPACITY ...
Page 115: ...93 LIFTING CAPACITY ...