67
PERIODIC SERVICE
A
When using an oil of different maker or viscosity from
the previous one, remove all of the old oil.
Never mix two different types of oil.
A
If oil level is low, do not run engine.
B
Checking Transmission Fluid Level
1. Park the machine on a flat surface, lower the
implement and shut off engine.
2. To check the oil level, draw out the dipstick, wipe it
clean, replace it, and draw it out again. Check to see
that the oil level lies between the two notches.
If the level is too low, add new oil to the prescribed
level at the oil inlet.
(See "LUBRICANTS" in "MAINTENANCE" section.)
A
If oil level is low, do not run engine.
B
Checking Coolant Level
To avoid personal injury:
A
Do not remove radiator cap while coolant is
hot. When cool, slowly rotate cap to the first
stop and allow sufficient time for excess
pressure to escape before removing the cap
completely.
1. Check to see that the coolant level is between the
"FULL" and "LOW" marks of recovery tank.
2. When the coolant level drops due to evaporation, add
soft water only up to the full level.
In case of leakage, add anti-freeze and soft water in
the specified mixing ratio up to the full level.
(See "Flushing Cooling System and Changing
Coolant" in "EVERY 2 YEARS" in "PERIODIC
SERVICE" section.)
A
If the radiator cap has to be removed, follow the
caution above and securely retighten the cap.
A
Use clean, fresh soft water and anti-freeze to fill the
recovery tank.
A
If water should leak, consult your local KUBOTA
Dealer.
(1) Dipstick
(2) Oil inlet
(A) Oil level is acceptable within this range.
(1) Recovery tank
(A) "FULL"
(B) "LOW"